跳至主要内容
临床试验/NCT05432609
NCT05432609进行中(未招募)不适用

Standardization and Reproducibility Regarding Scanning Procedures and Measurements of Weight-bearing Cone Beam CT in the Lower Extremity

Bispebjerg Hospital1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2021年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
40
试验地点
1
主要终点
Measurement of patellofemoral indices

研究概览

简要总结

Cone Beam CT (CBCT) of the knee is gaining interest, especially regarding patients suffering from patellofemoral instability. With this study investigators wish to investigate the day-to-day, test-retest reliability of weight bearing (WB) and non-weight bearing (NWB) CBCT of the knee in healthy participants and patients suffering from trochlear dysplasia. The participants and patients will be scanned in the following positions: 0° WB, 0° NWB, 20° WB, 20° NWB on two separate days. The trochlear dysplasia patients will furthermore be scanned 6 months postoperatively.

The aim is to develop af protocol on how to both position patients during weight bearing scannings as well as a protocol on how to prepare the cross sectional images before measurements.

详细描述

Investigators expect that scans performed with CBCT will show a clear change in the TT-TG distance when comparing scans performed in two different degrees of flexion of the knee. Investigators expect a discrete change in the TT-TG distance between non-weight bearing and weight-bearing state of the same degree of flexion. Investigators expect that other radiological targets for assessing patellofemoral instability, e.g. in trochlear dysplasia patients will change between the different scan situations. In addition, investigators expect that the TT-TG distance measurement method has a high reproducibility of intra- and in-terobserver variation as well as over time with repeated scans. The reproducibility is expected to be at least as good or above existing 2D measurement methods on conventional scans. In patients with trochlear dysplasia, a greater TT-TG distance is expected than in healthy controls. In addition, differences in TT-TG distance between flexion/extension as well as between non-weight bearing and weight bearing condition are expected to be greater than in healthy controls. In addi-tion, investigators expect to be able to detect a correlation between controlled changes in the position of the foot which will lead to passive changes in the TT-TG distance.

The purpose of the study is:

  • To investigate changes in TT-TG distance in CBCT scans of the knee joint, in healthy con-trols as well as in trochlear dysplasia patients, in two predefined degrees of flexion (0 ° i.e. fully stretched position; 20 ° flexion), in respectively weight-bearing loaded and unloaded position
  • To investigate the day-to-day reliability of the measured TT-TG distance, knee flexion angle and other radiological measurements regarding patellofemoral instability, at two separate CBCT scan sessions in patients with trochlear dysplasia compared with healthy controls
  • To investigate changes in the TT-TG distance in trochlear dysplasia patients before and after surgery in terms of evaluation of the patellofemoral instability

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Other

入排标准

年龄范围
18 Years 至 39 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Substudy 1:Healthy
  • Male or female aged 18-39 years
  • Must be able to stand on one leg for 30 seconds
  • Diagnosed with trochlear dysplasia, in addition healthy
  • Male or female aged 18-39 years
  • Patients scheduled to either a trochlear plastic surgery + MPFL reconstruction or Elmslie- Trillat + MPFL reconstruction + trochlear plastic surgery
  • Must be able to stand on one leg for 30 seconds

排除标准

  • Current knee injury and / or knee pain.
  • Known rheumatoid and / or connective tissue disease.
  • Previous treatment requiring knee injury and / or knee surgery.
  • Pregnancy
  • Known rheumatoid and / or connective tissue disease
  • Previous treatment requiring knee injury and / or knee surgery.
  • Patients who need distalization
  • Pregnancy

结局指标

主要结局

Measurement of patellofemoral indices

时间窗: 1 year

Intra and interrater reliability and day to day repeatability

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Signe Brinch

Principal investigator, MD, PhD student

Bispebjerg Hospital

研究点 (1)

Loading locations...

相似试验