MyoStrain CMR for the Detection of Cardiotoxicity
- Conditions
- Heart FailureChemotherapeutic ToxicityCardiotoxicity
- Interventions
- Diagnostic Test: MyoStrain
- Registration Number
- NCT03543228
- Lead Sponsor
- Myocardial Solutions
- Brief Summary
The Prefect Pilot Study evaluates the use of the EC approved MyoStrain SENC CMR Imaging System to detect cardiotoxicity from drugs used to treat cancer (e.g. Breast Cancer and Lymphomas).
- Detailed Description
The study is a prospective, observational, single center, observational clinical study that will enroll up to 50 patients undergoing chemotherapy and/or targeted therapy with or without concomitant radiotherapy for the treatment of breast cancer or lymphoma. Enrolled subjects will be evaluated with the MyoStrain SENC CMR Imaging System that measures myocardial strain during standard Cardiac Magnetic Resonance imaging at baseline through 6 month follow-up.
The MyoStrain SENC CMR Imaging System has been approved with an EC Certificate according to Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4 (CE 657862) in respect of: Design, development and manufacture of software for the quantification of cardiac MRI images. MyoStrain measures the contraction of heart muscle in one heartbeat per image plane. With 6 image planes (3 short axis \& 3 long axis), a complete measure of the health of the myocardium, both regionally and globally, can be obtained within a minute without requiring contrast injection or a breath-hold.
Heart health will be monitored throughout cancer therapy to quantify the toxic effects of chemotherapy with or without a reduction in traditional measures such as ejection fraction, and the ability to reverse observed cardiotoxicity with standard heart failure therapy.
The goal of the study is to determine the ability to detect subclinical cardiotoxicity before extensive damage causes the reduction in traditional measures, which are currently used to categorize heart failure and serve as the basis of treatment guidelines.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 63
- Undergoing Chemotherapy for Cancer Treatment
- Provided Written Informed Consent
- Contraindication to Magnetic Resonance Imaging
- Pregnancy
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description MyoStrain MyoStrain During standard chemotherapy and/or targeted treatment for breast cancer or lymphoma, MyoStrain will be used during standard cardiac magnetic resonance imaging to evaluate the change in myocardial contraction regionally and globally to detect cardiotoxicity and management of myocardial dysfunction.
- Primary Outcome Measures
Name Time Method Accuracy of MyoStrain to Detect Cardiotoxicity 6 months Sensitivity of MyoStrain CMR Software to quantify myocardial dysfunction before changes in traditional measures including ejection fraction as ascertained by Biomarkers including BNP, Troponin, and SF-36 Quality of Life. Sensitivity will be calculated by looking at paired t-test evaluations comparing follow-up time points to baseline as to whether changes associated with administration of chemotherapy agents and/or heart failure therapy are detected.
- Secondary Outcome Measures
Name Time Method Cardiotoxicity Incidence of Chemotherapy Drugs 6 months Incidence of subclinical dysfunction during chemotherapy as determined by CMR detection of the amount and locations of declining segmental myocardial contraction with MyoStrain software that measured the ability of the myocardium to contract in 37 segments of the heart (16 longitudinal strain measurements from 3 short axis planes \& 21 circumferential strain segments from 3 long-axis planes).
Cardiotoxicity Risk Stratification 6 months Ability to detect risk of developing cardiotoxicity by quantifying subclinical myocardial dysfunction in patients with segmental strain at baseline exceeding predefined thresholds. Higher risk patients will be defined as 2 or more segments \> -10% with MyoStrain measurements OR 9 or more segments \> -17%; Lower risk patients will be the remaining patients. The changes in strain for each patient category will be evaluated by changes in segmental strain during oncology therapy.
Efficacy of Heart Failure Therapy to Treat Cardiotoxicity 6 months Impact of heart failure medications to improve subclinical dysfunction, calculated by improvement in previously worsened segmental myocardial contraction with MyoStrain software that measured the ability of the myocardium to contract in 37 segments of the heart (16 longitudinal strain measurements from 3 short axis planes \& 21 circumferential strain segments from 3 long-axis planes).
Trial Locations
- Locations (1)
Marien Krankenhaus GmbH
🇩🇪Hamburg, Germany