Prospective Multicentre Registry of High-Purity Type I Collagen Nerve Wrapping in Peripheral Nerve Procedures: Early Clinical Outcomes
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 40
- 试验地点
- 2
研究概览
简要总结
This prospective multicentre observational registry evaluates early clinical outcomes following the use of High-Purity Type I Collagen (HPTC) as a circumferential nerve wrap during peripheral nerve procedures. Eligible procedures include nerve repair, coaptation, grafting, nerve transfers, and decompressions in the upper and lower limbs.
Primary outcomes include early motor recovery assessed using the Medical Research Council (MRC) motor grading system. Secondary outcomes include sensory recovery, neuropathic pain, patient-reported functional outcomes, complication rates, and patient satisfaction assessed at standardized postoperative intervals up to two months.
详细描述
Peripheral nerve surgery outcomes are often compromised by perineural fibrosis, neuroma formation, and unpredictable axonal regeneration. High-Purity Type I Collagen (HPTC) is a bioengineered resorbable collagen membrane designed to act as a biologic scaffold and perineural barrier, potentially reducing scar adherence and facilitating nerve gliding.
This prospective registry enrolls adult patients undergoing peripheral nerve procedures where HPTC is used as an adjunct circumferential nerve wrap. Functional motor recovery, sensory recovery, pain scores, patient-reported outcomes, and complications will be systematically documented at baseline and follow-up intervals up to four months. This registry aims to generate real-world, multicentre evidence regarding the safety and early clinical effectiveness of HPTC nerve wrapping.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 70 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age 18 to 70 years
- •Patients undergoing peripheral nerve procedures including: Primary nerve repair, Nerve coaptation, Nerve grafting, Nerve transfer, Revision nerve decompression
- •Upper or lower limb nerve involvement
- •Intraoperative use of HPTC nerve wrap
- •Ability to comply with follow-up
- •Written informed consent provided
排除标准
- •Active infection at the surgical site
- •Known hypersensitivity to collagen products
- •Severe uncontrolled systemic illness
- •Pregnancy or lactation
- •Re-operation at the same nerve site within the previous 6 months