Respiratory Measurement of Volume Change Using Accelerometer, Thermographic Camera Electrical Impedance Tomography and Motion Correlation Analysis Using Mattress Sensor in Healthy Individuals
- Conditions
- Healthy Adult
- Interventions
- Device: accelometerDevice: thermographic cameraDevice: Electrical Impedance TomographyDevice: Mattress Sensor
- Registration Number
- NCT04964245
- Lead Sponsor
- Yonsei University
- Brief Summary
Tidal volume can be the most important technical indicator for ventilation. Measuring the volume of breathing can be used as an indicator of how effective a patient's gas exchange is, and as a predictive indicator of the statue of respiratory disease indirectly. These Tidal volumes can be measured using spirometry and pneumotachograph, and the breathing volume and the rate of airflow can directly or indirectly evaluate the lung function of the patient.
However, spirometry has limitations that patients who are difficult to measure, and that it is difficult to measure in bed. In this work, the movement of the thorax due to breathing is measured in a non-invasive manner (accelerometer, thermographic camera) and the accuracy is compared through changes in thoracic impedance obtained through Pulmovista 500. Furthermore, we would like to correlate the motion of the measured object through a mattress sensor.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- Male
- Target Recruitment
- 10
- over 19, under 50 years old and common BMI
- non-smoking, person without cardiopulmonary disease.
- smoking, cardiopulmonary, infectious diseases.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Respiration monitoring group Electrical Impedance Tomography The respiration is simultaneously measured by accelerometer, thermographic camera, Impedance Tomography, and mattress sensor. Respiration monitoring group accelometer The respiration is simultaneously measured by accelerometer, thermographic camera, Impedance Tomography, and mattress sensor. Respiration monitoring group thermographic camera The respiration is simultaneously measured by accelerometer, thermographic camera, Impedance Tomography, and mattress sensor. Respiration monitoring group Mattress Sensor The respiration is simultaneously measured by accelerometer, thermographic camera, Impedance Tomography, and mattress sensor.
- Primary Outcome Measures
Name Time Method The accuracy of respiration measurements about 20 min The accuracy respiration measurements between thermographic camera, accelerometer, electrical impedance tomography, and mattress sensor.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Severance Hospital, Yonsei University Health System
🇰🇷Seoul, Korea, Republic of