Results of Different Location of Ahmed Glaucoma Valve Implantation in Refractory Glaucoma, Superior Versus Inferior
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 106
研究概览
简要总结
Purpose:To compare the efficacy and safety of Ahmed Glaucoma Valve (AGV) implantation in the superior versus inferior quadrants.
Methods: In a non-randomized clinical trial and over a period of two years, consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included best corrected visual acuity (BCVA), intraocular pressure (IOP), number of glaucoma medications, complications and success rate (defined as at least 30% IOP reduction below preoperative values and 5<IOP<22 mmHg with or without glaucoma medications). Other criteria for failure included implant removal, additional glaucoma surgery, phthisis bulbi or loss of light perception.
研究设计
- 研究类型
- Interventional
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with refractory glaucoma who need AGV implantation
排除标准
- •Eyes with less than 3 months follow-up
- •Severe conjunctival adhesions and scarring for the site of surgery
- •Presence of thin sclera and staphyloma for the site of surgery
- •The presence or anticipated need for silicone oil for superior implantation
- •Active neovascular glaucoma for inferior implantation