Evaluation of the PillCam™ Colon Capsule Endoscopy (PCCE) Night Procedure
试验速览
- 阶段
- 3 期
- 状态
- 已完成
- 入组人数
- 49
- 试验地点
- 2
- 主要终点
- Colon cleansing level score
研究概览
简要总结
The purpose of this study is to evaluate the effect of the night procedure in regards to colon cleansing level and capsule excretion rate.
详细描述
The evaluation of subjects with suspected colonic disease includes endoscopic imaging by colonoscopy and radiologic imaging such as air-contrast barium enema, or CT colonography. The Given® Diagnostic System offers an alternative approach for endoscopic visualization of the colon using capsule endoscopy, an ingestible device which contains imagers, light sources, a power source and a RF transmitter. Advantages of the Given® Diagnostic System include the elimination of the need for sedation, the minimally invasive, painless nature of the exam, and the ability to pursue normal daily activities immediately following the procedure . Furthermore, compared to standard colonoscopy, the Given® Diagnostic System may be more readily accepted by the subjects, thereby improving subjects' willingness to undergo a diagnostic evaluation of the colon and comply with colorectal cancer screening recommendations.
The PillCam™ SB capsule (formerly M2A® Capsule) that was FDA-approved in August 2001 for small bowel evaluation has been ingested to date by more than 500,000 people worldwide and is well accepted by patients and physicians as well as the processional societies. However, adequate visualization of the colon cannot be achieved with the standard PillCam™ SB capsule because of the anatomical and physiological properties of the colon which are significantly different than the small bowel. Moreover, other issues that limit the evaluation of the colonic mucosa by the standard PillCam™ SB procedure include an unsatisfactory level of colon cleanliness and slow progression of the PillCam™ SB capsule through the colon during the desired examination time. Therefore, the development and introduction of a specially designed, customized colon capsule combined with a dedicated capsule colonoscopy procedure protocol will allow for more efficient evaluation of the colonic mucosa. This is expected to improve the capability of the Given® Diagnostic System to detect colonic pathologies and to serve as a diagnostic and screening tool for colonic disease. Further details of the PillCam™ Colon Capsule Endoscope (PCCE) can be found in the device description section.
This is a pilot study that is designed to evaluate the level of cleanliness and visualization of colon achieved by colon capsule endoscopy when using Night procedure regimens for preparation of the colon.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 50 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subject is between the ages of 50-75 years and has an indication to undergo colonoscopy: At least 75% of total cases OR
- •Subject is 18-50 suspected/known to suffer from large bowel disease and was clinically referred for colonoscopy (e.g. rectal bleeding, melena, positive FOBT, recent change of bowel habits, CRC screening, UC, positive findings on a GI radiographic study - no more than 25% of total cases
排除标准
- •Subject has dysphagia or any swallowing disorder
- •Subject has severe Congestive heart failure (NYHA II or IV)
- •Subject has renal insufficiency
- •Subject has had prior abdominal surgery of the gastrointestinal tract other than uncomplicated procedures that would be unlikely to lead to bowel obstruction based on the clinical judgement of the investigator
- •Subject has a cardiac pacemaker or other implanted electromedical device.
- •Subject has any allergy or other known contraindication to the medications used in the study
- •Subject is expected to undergo MRI examination within 7 days after ingestion of the capsule.
- •Subject with any condition believed to have an increased risk for capsule retention such as Crohn's disease, intestinal tumors, radiation enteritis, or NSAID enteropathy,
- •Subject has any condition, which precludes compliance with study and/or device instructions.
- •Women who are either pregnant or nursing at the time of screening, who intend to be during the study period, or are of child-bearing potential and do not practice medically acceptable methods of contraception.
- •Subject suffers from life threatening conditions
- •Subject currently participating in another clinical study
研究组 & 干预措施
1
Patients that are indicated for colonoscopy or who are suspected or known to suffer from colonic diseases.
干预措施: PillCam™ (Capsule Endoscopy) (Device)
结局指标
主要结局
Colon cleansing level score
时间窗: within 7 days
Transit time in the different GI regions until excretion
时间窗: within 7 days
次要结局
- Number of complete capsule procedure(within 7 days)
- Accuracy parameters of PCCE, compared to colonoscopy(within 7 days)
- Patient subjective assessment questionnaires(within 7 days)