BIOTRONIK - Safety and Clinical PerFormance of the Drug Eluting Absorbable Metal Scaffold (DREAMS 2nd Generation) in the Treatment of Subjects With de NOvo Lesions in NatiVE Coronary Arteries: BIOSOLVE-II

Biotronik AG25 个研究点 分布在 8 个国家目标入组 123 人开始时间: 2013年10月最近更新:
适应症

试验速览

阶段
不适用
发起方
Biotronik AG
入组人数
123
试验地点
25
主要终点
In segment Late Lumen Loss

研究概览

简要总结

BIOSOLVE-II is a prospective, international, multicenter, First in Man study. The purpose of this study is to assess the safety and clinical performance of the drug eluting absorbable metal scaffold (DREAMS 2nd Generation).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subject is > 18 years and < 80 years of age
  • Written subject informed consent available prior to PCI
  • Subjects with stable or unstable angina pectoris or documented silent ischemia
  • Subject eligible for PCI
  • Subject acceptable candidate for coronary artery bypass surgery
  • Subjects with a maximum of two single lesions in two separate coronary arteries which have to be de novo lesions.
  • Reference vessel diameter between 2.2-3.8 mm by visual estimation
  • Target lesion length ≤ 21 mm by visual estimation
  • Target lesion stenosis by visual estimation, assisted by QCA / IVUS: > 50% - < 100%
  • Eligible for Dual Anti Platelet Therapy (DAPT)

排除标准

  • Pregnant or breast-feeding females or females who intend to become pregnant during the time of the study
  • Evidence of myocardial infarction within 72 hours prior to index procedure
  • Subjects with a ≥2 fold CK level or in absence of CK a ≥3 fold CKMB level above the upper range limit within 24 hours prior to the procedure
  • Unprotected left main coronary artery disease
  • Three-vessel coronary artery disease at time of procedure
  • Thrombus in target vessel
  • Subject is currently participating in another study with an investigational device or an investigational drug and has not reached the primary endpoint yet
  • Planned interventional treatment of any non-target vessel within 30 days post-procedure
  • Subjects on dialysis
  • Planned intervention of the target vessel within 6-month after the index procedure
  • Ostial target lesion (within 5.0 mm of vessel origin)
  • Target lesion involves a side branch >2.0 mm in diameter
  • Documented left ventricular ejection fraction (LVEF) ≤ 30%
  • Heavily calcified lesion
  • Target lesion is located in or supplied by an arterial or venous bypass graft
  • The target lesion requires treatment with a device other than the pre-dilatation balloon prior to scaffold placement (including but not limited to, rotational atherectomy, cutting balloon etc.)
  • Known allergies to: Acetylsalicylic Acid (ASA), Heparin, Contrast medium, Sirolimus, or similar drugs; or the scaffold material
  • Impaired renal function (serum creatinine > 2.5 mg/dl or 221 mmol/l, determined within 72 hours prior to intervention)
  • Subject is receiving oral or intravenous immuno-suppressive therapy (e.g., inhaled steroids are not excluded) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus, but not including diabetes mellitus)
  • Proximal or distal to the target lesion located stenosis that might require future revascularization or impede run off detected during diagnostic angiography
  • Life expectancy less than 1 year
  • Planned surgery or dental surgical procedure within 6 months after index procedure
  • In the investigators opinion subjects will not be able to comply with the follow-up requirements

结局指标

主要结局

In segment Late Lumen Loss

时间窗: 6 months post index procedure

次要结局

  • Target Lesion Failure (TLF), defined as composite of cardiac death, target vessel Q-wave or non-Q-wave Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), clinically driven Target Lesion Revascularisation (TLR)(1, 6, 12, 24 and 36 months)
  • Scaffold thrombosis rate(1, 6, 12, 24 and 36 months)
  • Late Lumen Loss in scaffold(6 and 12 months)
  • Procedure success(During the hospital stay to a maximum of the first seven days post index procedure)
  • Device success(Day 0)
  • In-scaffold and in-segment Binary Restenosis Rate(6 and 12 months)
  • In-scaffold and in-segment Percent Diameter Stenosis(6 and 12 months)
  • Late Lumen Loss in segment(12 months)

研究者

发起方
Biotronik AG
申办方类型
Industry
责任方
Sponsor