Neonatal Mask Seal; a Randomised Controlled Trial of Two-handed Versus One-handed Hold for Delivering Positive-pressure Ventilation With a Facemask in Preterm and Term Infants: The NeoSeal Study

University College Dublin1 site in 1 country110 target enrollmentJanuary 27, 2025

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Neonatal Intensive Care
Sponsor
University College Dublin
Enrollment
110
Locations
1
Primary Endpoint
Mask leak
Status
Recruiting
Last Updated
last year

Overview

Brief Summary

When babies can't breathe effectively, we can use a facemask to give them breaths and oxygen. The mask can be held with one or two hands, depending on the preference of the doctor. Both types of mask holds are recommended in international guidelines, but it is unclear which one is better for the baby. If a lot of air is leaking around the mask, it means that the baby is not getting the full breathing support that the healthcare providers are trying to give. There currently is not enough evidence to say which type of hold is better to reduce this potential leaking of air.

In this study, the investigators will compare two different ways of holding a mask on a baby's face to help them breathe. Each baby will be randomly allocated to either a one-handed or a two-handed mask hold, and the investigators will measure how much air leaks out around the mask during each breath. Any baby in the neonatal unit may be included in this study.

Detailed Description

This study will compare the measured leak in mask ventilation delivered by a healthcare professional in the neonatal team, using a one-handed versus a two-handed hold with a standardised mask size and shape. This is to assess the two-handed technique as a potential first-line approach in neonatal bag-mask ventilation. The handholds will be assessed by a randomised controlled trial, with the two-handed hold as the intervention and the one-handed hold as the control. The population that will be studied is neonates in the neonatal intensive care unit (NICU), at any gestation, who the clinical team have decided to intubate. A member of the research team, who will provide an out-of-hours on call service, will attend the event. The relevant outcomes will be measured by the Monivent Neo100, which will be set up by the research team. Standardised masks, as used per local protocol, will be used, with the sensor module placed between that and the T-piece with an adaptor. The outcomes will assess the effectiveness of both the intervention and control, including ventilation parameters recorded by the Monivent Neo100 and the clinical stability of the patient. The primary outcome of this study is the percentage mask leak. A research team member will record data for primary and secondary outcome. The event will be filmed for post-hoc video analysis. The outcome assessor will be blinded to the group allocation. This research project will take place over 24 months, with an interim analysis to ensure recruitment is projected to achieve sample size.

Registry
clinicaltrials.gov
Start Date
January 27, 2025
End Date
December 2026
Last Updated
last year
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • All term and preterm neonates in the neonatal unit who the clinical team have decided to intubate, with or without pre-medication and who require mask ventilation prior to intubation attempt.

Exclusion Criteria

  • Neonates with a congenital malformation that would impact mask seal will not be included.

Outcomes

Primary Outcomes

Mask leak

Time Frame: Over a maximum of 20 minutes

Mask leak percentage, as measured by the Monivent Respiratory Function Monitor (RFM). Collected over a minimum of 5 breaths. Maximum of 2 episodes of facemask ventilation will be collected, with values averaged.

Secondary Outcomes

  • Lowest oxygen saturation(Over a maximum of 20 minutes)
  • Highest supplemental FiO2 used during facemask ventilation(Over a maximum of 20 minutes)
  • Positive inspiratory pressure during facemask ventilation(Over a maximum of 20 minutes)
  • Percentage of obstructed breaths during facemask ventilation(Over a maximum of 20 minutes)
  • Tidal volume during facemask ventilation(Over a maximum of 20 minutes)
  • Number of times facemask position is adjusted during facemask ventilation(Over a maximum of 20 minutes)
  • Duration of facemask ventilation(Over a maximum of 20 minutes)
  • Crossover to other handhold(Over a maximum of 20 minutes)
  • User opinion of mask hold(Over a maximum of 20 minutes)
  • Lowest heart rate(Over a maximum of 20 minutes)

Study Sites (1)

Loading locations...

Similar Trials