跳至主要内容
临床试验/NCT04510779
NCT04510779已完成不适用

Monitoring Heart Failure Patients Using Heart Rate Variability Measured by the Apple Watch

Tufts Medical Center2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2022年5月9日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
10
试验地点
2
主要终点
Difference of Standard Deviation of NN Intervals upon Discharge Compared to Admission

研究概览

简要总结

This is a pilot/feasibility study on the accuracy of HRV as measured by the Apple Watch on heart failure patients who are admitted to the hospital with heart failure exacerbation. The primary aim is to observe a statistically significant improvement in the HRV of acutely decompensated heart failure patients upon discharge when compared to admission, implying the utility of HRV measured by Apple Watch as a monitor for cardiovascular health.

详细描述

Heart failure (HF) is a complex clinical syndrome. It is caused by structural or functional impairments, which interfere with the ability of heart muscles to fill or eject blood. The prevalence of HF exceeds 7 million in the United States alone.(1) Despite improving survival, HF hospitalization rates has remained stable, which reflects persisting difficulties in managing existing disease. (2) Specifically, readmission rates may be as high as 50% by 6 months after an admission for HF management. (2) Caring for HF patients exceeds 30 billion annually and is largely driven by hospitalizations.2 Innovative, at-home surveillance tools are needed to reduce hospital admissions and to drive down the overall societal burden of this disease. (3)

HF is characterized by periodic exacerbations due to volume overload and fluid congestion that impairs perfusion to the organs.(2) Accurate assessment of volume status is, therefore, key for early detection of impending exacerbation. Currently, there is no single, objective method of assessment, relying on a combination of tools including physical examination, weight, pulmonary artery catheter or echocardiography.(4) However, these measures are subjective, invasive, or impractical for monitoring patients at home. Unique body habitus and comorbidities of individual patient further complicates assessment of volume status.(4) The future of heart failure management, therefore, lies in the development of a telemonitoring system that is convenient to use and accessible for patients at home, while quantitatively understanding individual characteristics.(4)

Cardiovascular health is closely related to the imbalances of the autonomic nervous system.(5) Heart rate variability (HRV), the degree of fluctuation in the interval between consecutive heartbeats, has been recognized as a reliable marker of autonomic activity.(5) HRV has been shown to be depressed in patients with congestive heart failure (CHF) and to correlate with disease severity. (6) Furthermore, abnormal HRV parameters are independently associated with incident CHF in asymptomatic, older adults. (7)

HRV is conventionally measured using a 24-hour Holter monitor, which is sensitive, but inconvenient and impractical for home monitoring.(5) Newer studies have shown not only the reliability of short term (5-minute) or ultra-short term (<5 minute) analysis of electrocardiographic recordings, but also that of wearable monitors amenable for use at home.(9-11) In particular, HRV parameters measured by Apple Watch (Cupertino, California) were shown to agree with those measured by a validated chest best heart rate monitor.(12)

The usefulness of the study is to validate the utility of wearable heart monitors such as the Apple Watch in accurately measuring heart rate variability, a dynamic marker of cardiovascular health, and correlating it with the health status specifically of heart failure patients. Validating this will allow wearable monitors to record HRV remotely from home, facilitating telemonitoring and preventing hospitalizations.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
22 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age > or = 22
  • Patients admitted to Tufts Medical Center for acute decompensated heart failure
  • Left ventricular ejection fraction greater than 35%
  • Able to consent

排除标准

  • Pacemaker rhythm
  • Arrhythmia, e.g. atrial fibrillation, atrial flutter, frequent ectopic beats
  • prior history of heart transplant or ventricular assist device

结局指标

主要结局

Difference of Standard Deviation of NN Intervals upon Discharge Compared to Admission

时间窗: 1-2 Weeks

Standard Deviation of NN Intervals is a time domain heart rate variability parameter. The value upon discharge after medical management should be statistically greater compared to admission value.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验