Artificial Intelligence-assisted Common Bile Duct Stent Selection in Endoscopic Retrograde Cholangiopancreatography

Conditions
Stenosis of Bile Duct
Endoscopic Retrograde Cholangiopancreatography
Registration Number
NCT05321472
Lead Sponsor
Shandong University
Brief Summary

Common bile duct stenosis is an important indication for endoscopic retrograde cholangiopancreatography(ERCP). Appropriate selection of bile duct stent size is not only conducive to successful stent implantation but also to improve the prognosis of patients. Currently, the selection of stent specifications is based on the operator's empirical estimation, which is not only not accurate but also increases the radiation exposure time, causing unnecessary harm to both the operator and the patient. Our objective is to develop an artificial intelligence algorithm to automatically select appropriate stent.

Detailed Description

Endoscopic Retrograde Cholangiopancreatography (ERCP) is an operation with high risk. Common bile duct stone and stenosis are important indications. The quality control of ERCP is the key to improve its success rate and reduce complications, which has received great attention. In 2015, the American Society of Gastrointestinal Endoscopy/American College of Gastroenterology (ASGE/ACG) issued ERCP quality control indicators, among which biliary stent placement and radiographic fluoroscopy time are important intraoperative quality control indicators.

The selection of appropriate biliary stent size is not only conducive to successful stent implantation but also to improve the prognosis of patients. Choose a stent of appropriate length. The proximal side of the stent should be 1cm above the obstruction segment, and the distal tail should be located just outside the nipple. The length of the stent can be determined by measuring the distance between the proximal end of the obstruction and the nipple under X-ray.

Current stent size selection is based on the operator's empirical estimation :(1) estimate the distance by endoscope diameter or cone length or catheter marking; (2) By retracting the guidewire, calculate the distance of the guidewire retracting between two points to estimate the length of the stent.The long radiation exposure time results in unnecessary injuries to both the operator and the patient.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
600
Inclusion Criteria
  • Patients older than 18 years old who underwent ERCP
Exclusion Criteria
  • failed cholangiopancreatography caused by failed intubation, gastric retention, duodenal disease and so on
  • patients proved no stenosis in common bile duct
  • poor cholangiograms due to the lack of contrast agent or insufficient filling of contrast agent (cholangiograms without the completed CBD or thumbnails)

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
The accuracy of the calculated length of the stents by the artificial intelligence6 months

The length of the stent was calculated "the length from the stenosis to the papilla+2cm".The length of the stent selected by experts is the gold standard

Secondary Outcome Measures
NameTimeMethod
The accuracy of the segmentation of the artificial intelligence4 months

The accuracy of the segmentation of the common bile duct, duodenoscopy and stenosis lesions by the artificial intelligence