Efficacy and Safety of Eyetronix Flicker Glasses to the Treatment of Anisometropic Amblyopia
- Conditions
- Amblyopia, Anisometropic
- Interventions
- Device: EFG groupDevice: Patching group
- Registration Number
- NCT02970708
- Brief Summary
To evaluate the efficacy and safety of Eyetronix Flicker Glassess therapy in treating anisometropic amblyopia.
- Detailed Description
A total of 176 children with anisometropic amblyopia, aged 4 to 13 years, will randomize to receive patching or Eyetronix Flicker Glasses treatment in a 1:1 ratio.Eyetronix Flicker Glasses, a lightweight spectacle frame with liquid crystal lenses that provide direct square-wave alternating occlusion, will be used at a pre-programmed temporal frequency. Patching is a traditional treatment of amblyopia. The best corrected visual acuity, contrast sensitivity, binocular function,visual evoked potential and functional MRI will be measured at baseline and follow-up visits to assess the improvement of amblyopia.Feedback information from the questionnaires will be used to evaluate the compliance and adverse effects.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 176
- aged from 4 to 13 years old
- the best corrected visual acuity in the amblyopic eye is no more than 0.1logMAR, with two lines or more of difference between the two eyes
- anisometropia is defined as an inter-ocular spherical refractive error difference of 1.00 D or more or a cylindrical difference of 1.50 D or more.
- no amblyopia treatment one month prior to the study except refractive correction.
- myopia is less than -6.00D or hyperopia is less than +9.00D, strabismus was less than 20 prism diopters
- willing to participate in this study and be able to follow up on time
- ocular disease and other disease that have an influence on the visual acuity
- history of ocular surgery that have an influence on the visual acuity
- the patient is receiving other amblyopia treatment except refractive correction
- a family or personal history of seizures
- the patient is using some medicine that may have an influence on visual acuity
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description EFG group EFG group amblyopia in EFG group will receive Eyetronix Flicker Glassess treatment. Patching group Patching group amblyopia in patching group will receive patching treatment.
- Primary Outcome Measures
Name Time Method best corrected visual acuity 6 months have an improvement of best corrected visual acuity in the amblyopic eyes
- Secondary Outcome Measures
Name Time Method contrast sensitivity function 6 months have an improvement of contrast sensitivity in the amblyopic eyes
visual evoked potential 6 months P100 latency decrease and N75-P100 amplitude increase in the amblyopic eye.
functional MRI 6 months the visual cortex activity have an improvement
stereocuity 6 months have an improvement of stereocuity in the amblyopic eyes
best corrected visual acuity a year and a half have an improvement of best corrected visual acuity in the amblyopic eyes