跳至主要内容
临床试验/NCT00214760
NCT00214760终止3 期

Phase 3 Randomised, Prospective Study Comparing the PMMA and the Resorbable PEGT/PBT Centralizer by the Uncemented BIHAPRO Total Hip Prosthesis

Biomet Nederland BV2 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2005年5月1日最近更新:
适应症

试验速览

阶段
3 期
状态
终止
发起方
入组人数
70
试验地点
2
主要终点
Alignment

研究概览

简要总结

The purpose of this study is to analyse if the alignment of the stem and the number of complications of the new resorbable PEGT/PBT centralizer are comparable to the standard PMMA centralizer during the placement of an uncemented Bihapro hip prosthesis.

详细描述

For a correct placement and early fixation of an uncemented hip prosthesis, a centralizer is used. Normally, the centralizer is made of PMMA, the same material as bone cement. When a revision is needed, PMMA is difficult to remove, which is one of the reason not to use a cemented hip prosthesis. With a PMMA centralizer, still PMMA will remain in the bone and needs to be removed in case of a revision. PEGT/PBT is a reabsorbable material, which gives stability during the first month after the placement of the hip prosthesis. However, PEGT/PBT is reabsorped afterwards and, therefore, will not interfere with a revision procedure.

The goal of this study is to analyse if the PEGT/PBT is as safe as PMMA in terms of alignment, direct postoperative complications and clinical results.

Therefore, 100 patients indicated for a cementless Bihapro hip prosthesis which have signed an informed consent are included and randomised over the used centralizers using a weighted randomisation method. All patients will be treated equally. The patients are examined preoperatively, 1 day, 6 weeks, 3, 6, 12, 24 en 48 months postoperatively using an X-ray, the Harris hip score and a patient questionnaire, the Womac and SF36.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age between 18 and 75 years
  • Diagnosis: Osteoarthritis
  • Indicated for a primary hip prosthesis

排除标准

  • Previous hip surgery
  • No informed consent
  • Active infection in hip
  • Immature skeleton
  • Rheumatoid arthritis, M. Paget

结局指标

主要结局

Alignment

时间窗: 0,3,6,12,24 months

Complications

时间窗: all time points

次要结局

  • Pain(0,3,6,12,24 months)
  • Function(0,3,6,12,24 months)

研究者

发起方
Biomet Nederland BV
申办方类型
Industry

研究点 (2)

Loading locations...