Skip to main content
Clinical Trials/NCT04012515
NCT04012515CompletedNot Applicable

Production of a Device to Obtain Continuous Ambulatory Vestibular Assessment (CAVA) - Electrode Pad Appraisal Trial

Julie Dawson2 sites in 1 country10 target enrollmentStarted: April 8, 2019Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
10
Locations
2
Primary Endpoint
The maximum duration of comfortable wear of electrode pad

Study Overview

Brief Summary

This trial requires healthy volunteers to wear a selection of CE marked electrodes for up to 30 days. The results from this trial will determine which electrodes should be used with the CAVA device, which is a medical device for monitoring dizziness.

Detailed Description

Dizziness is a common condition that is responsible for a significant degree of material morbidity and burden on our health service. There are multiple causes of dizziness, and these originate from pathologies affecting a large variety of different organ systems. Dizziness is usually episodic and short-lived, so when a patient presents to their health care provider, examination is often normal. As such, diagnosis is challenging and patients often experience significant delay in receiving a diagnosis. We have developed a device for monitoring dizziness and in 2018 we evaluated the device by undertaking a clinical trial involving healthy volunteers. Following the promising results from the first trial, we will conduct a second trial in 2019 on patients suffering from dizziness.

During the healthy volunteer trial, a minor issue was encountered relating to long-term daily wear of the device's electrode pads. Specifically, nine participants reported varying degrees of skin redness and inflammation beneath their electrode pads, mostly occurring after around two weeks of wear. The issue was self-limiting and resolved after a few days of non-wear. The team worked closely with a consultant dermatologist in order to monitor and manage this adverse event.

Since the issue was identified, the team has consulted with a number of people with relevant expertise in order to determine the causes of the issue and to find the most viable solution. Based on these discussions, we propose that the causes of this issue were due to a combination of wear duration, and/or repeated removal, and/or the specific type of electrode pad used. To confidently identify the cause of this issue and to evaluate a number of possible solutions, we intend to undertake a trial to evaluate the tolerability of alternative electrode pads and different patterns of wear.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Basic Science
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • Adults aged 18 and over.
  • Able to commit to 30 days of continuous wear of the electrode pads as per the study plan.
  • Own a telephone.

Exclusion Criteria

  • Potential participants who have a history of dermatological disease, damage around the forehead, or fragile skin.
  • Potential participants who have an allergy to plasters and/or medical adhesives.
  • Potential participants who have taken part in a previous CAVA trial.
  • Potential participants who are currently taking part in another trial.
  • Unable to follow the testing protocol.

Outcomes

Primary Outcomes

The maximum duration of comfortable wear of electrode pad

Time Frame: 1 month

The maximum duration of comfortable wear will be calculated for each combination of electrode pad and wear regime, and the longest duration will determine the best electrode pad for use with the CAVA device.

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Sponsor Investigator
Principal Investigator

Julie Dawson

Research Services Manager

Norfolk and Norwich University Hospitals NHS Foundation Trust

Study Sites (2)

Loading locations...

Similar Trials