BIOFLOW-III Canada Satellite Registry
- Conditions
- Myocardial IschemiaCoronary Artery Disease
- Registration Number
- NCT01880242
- Lead Sponsor
- Biotronik Canada Inc
- Brief Summary
For the majority of Coronary Artery Disease (CAD), treatment with Percutaneous Transluminal Coronary Angioplasty (PTCA) provides high initial procedural success. However, the medium to long-term complications range from rather immediate elastic recoil or vessel contraction to longer processes like smooth muscle cell proliferation and excessive production of extra cellular matrix, thrombus formation and atherosclerotic changes like restenosis or angiographic re-narrowing. The reported incidence of restenosis after PTCA ranges from 30%-50%. Such rates of recurrence have serious economic consequences. Bare Metal Stents (BMS), designed to address the limitations of PTCA, reduced the angiographic and clinical restenosis rates in de novo lesions compared to PTCA alone and decreased the need for CABG. BMS substantially reduced the incidence of abrupt artery closure, but restenosis still occurred in about 20%-40% of cases, necessitating repeat procedures. The invention of Drug Eluting Stents (DES) significantly improved on the principle of BMS by adding an antiproliferative drug (directly immobilized on the stent surface or released from a polymer matrix), which inhibits neointimal hyperplasia. The introduction of DES greatly reduced the incidence of restenosis and resulted in a better safety profile as compared to BMS with systemic drug administration. These advantages and a lower cost compared to surgical interventions has made DES an attractive option to treat coronary artery disease. This observational registry is designed to investigate and collect clinical evidence for the clinical performance and safety of the Orsiro Drug Eluting Stent System in an all-comers patient population in daily clinical practice.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 250
- Symptomatic coronary artery disease or documented silent ischemia
- Subject informed consent for data release
- Subject is geographically stable and willing to participate at all follow ups assessments
- Subject did not sign informed consent for data release
- Pregnancy
- Known intolerance to aspirin, clopidogrel, ticlopidine, heparin or any other anticoagulation/antiplatelet therapy required for PCI, stainless steel, sirolimus
- Planned surgery within 6 months of PCI unless dual antiplatelet therapy will be maintained
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Target Lesion Failure 12 months Composite of cardiac death, target vessel Q-wave or non-Q wave Myocardial Infarction (MI), Emergent Coronary Artery Bypass Graft (CABG), clinically driven Target Lesion Revascularization (TLR)
- Secondary Outcome Measures
Name Time Method Target Lesion Revascularization (TLR) 6 and 12 months Any repeat revascularization of the target lesion
Clinical Device Success 1 day (At time of intervention) Successful delivery and deployment of the investigational stent(s) at the intended target lesion (this includes successful delivery and deployment of multiple overlapping stents) and successful withdrawal of the stent delivery system with attainment of a final residual stenosis of less than 50% by visual estimation and without use of a device outside the assigned treatment strategy. Standard predilation catheters and post-dilation catheters (if applicable) may be used.
Target Lesion Failure 6 and 12 months Composite of cardiac death, target vessel Q-wave or non-Q wave Myocardial Infarction (MI), Emergent Coronary Artery Bypass Graft (CABG), clinically driven Target Lesion Revascularization (TLR)
Target Vessel revascularization (TVR) 6 and 12 months Any repeat revascularization of the target vessel
Stent Thrombosis 6 and 12 months Definite, Probable and Possible Stent Thrombosis
Clinical Procedure Success During the hospital stay to a maximum of the first seven days post index procedure Successful delivery and deployment of the investigational stent(s) at the intended target lesion (this includes successful delivery and deployment of multiple overlapping stents, if applicable) and successful withdrawal of the stent delivery system with attainment of a final residual stenosis of less than 50% of the target lesion as observed by visual estimate without using any adjunctive device\* without the occurrence of ischemia-driven major adverse cardiac event (ID-MACE) during the hospital stay to a maximum of the first seven days post index procedure.
Trial Locations
- Locations (2)
St. Michael's Hospital
🇨🇦Toronto, Canada
Centre Hospitalier de l'Université de Montréal (CHUM)
🇨🇦Montréal, Quebec, Canada