MedPath

The Effect of Tapping in the Venous Dilatation for Peripheral IV Access

Not Applicable
Completed
Conditions
Catheterization, Peripheral
Venous Dilatation
Interventions
Device: Tourniquet
Device: Device tapping
Device: Manual Tapping
Registration Number
NCT05265481
Lead Sponsor
University of Florida
Brief Summary

Peripheral intravenous cannulation (PIVC) is one of the most common interventions in medical practice. Venous dilatation is helpful for successful PIV placement. Several techniques include hot pack application, tourniquet, massaging, and tapping over the vein to increase vein caliber described in the literature. However, none of them has been rigorously studied. Therefore, there is still no 'best practice' on how to effect vein dilation in a standard way.

This study aims to investigate the effect of standardized tapping on venous dilatation with a massage device compared to manual non-standardized tapping and define a standard tapping technique using a device.

In this study, the investigators also aim to investigate the effect of tourniquet application with and without vein tapping effect on peripheral vein caliber as determined by ultrasound measurement.

Detailed Description

PIVC is one of the most common medical interventions in daily practice. Even though it seems like it should be an easy procedure, PIVC can be challenging.

Venous dilatation optimizes conditions for successful vein cannulation. Several techniques are described to affect venodilation, but none of them are standardized because they are done manually, and there will be individual variations among clinicians.

Tapping over the vein has been reported as an effective method. It has been hypothesized that tapping affects vein vaso-nervorum activation and local histamine release. Tapping or massage over the cannulation site is readily applied in busy medical practice, with a third of nurses using tapping or massage to promote venodilation. Tapping and massage are effective methods of vasodilatation to make the vein more prominent for venipuncture, with tapping more effective than massage (Ichimura et al.) There are limited data concerning the effect of tapping in PIVC and its standardization. In the current literature, there is no standard technique on how tapping should be performed.

Specific Aims:

* H0: Standardized tapping with a massage device is not an effective technique to dilate the peripheral veins for PIVC compared to manual tapping.

* H1: Standardized tapping with a device is a more effective technique to dilate peripheral veins for PIVC compared to manual tapping.

The investigators expect to learn to what degree a tourniquet increases peripheral vein size and to what degree that is augmented by tapping.

Research Plan:

This is a prospective non-randomized, controlled, non-invasive intervention study.

The investigators will visually and also with surface ultrasound inspect the upper extremity. The investigators will not get blood tests or X-rays for study purposes. The investigators will measure the venous diameter of a vein or veins on the back of the hand and deeper within the forearm and in the antecubital fossa using ultrasound. The investigators will use a survey including participant's demographics (age, gender, handedness, smoking history)

The investigators will use a portable ultrasound device (Butterfly iQ+, Butterfly Network, Inc., CT, USA) connected to an iPad to record ultrasound images (as pictures) and measure the diameter and cross-section area of the various veins. The investigators will take vein measurements from the dorsal hand, cubital, and mid-forearm regions. The investigators will take the measurements from the midline of the antecubital, volar side of the forearm, and dorsal hand regions. The investigators will put masking tapes on the skin as a reference point to make all the measurements from the same plane."

Then the investigators will determine the midpoint of the forearm, the antecubital site, and the volar wrist crease. The midpoint of this line will be the mid-forearm vein measurement site. The investigators will use superficial dorsal hand veins of the dorsal metacarpal region for the dorsal hand vein measurements. During the baseline measurements, the investigators will get the best image with ultrasound and then mark the skin to get all the measurements from the same cross-sectional area and place water-resistant tape with a scale.

The investigators will not use ultrasound gel or direct ultrasound probe application to the skin to prevent any possible ultrasound transducer-related venous compression. Instead, the investigators will sufficiently submerge the hand, forearm, and elbow in a fresh room temperature water-filled basin to allow precise vein caliber measurements with an ultrasound probe without any probe contact with the skin. This technique provides high-quality ultrasound images of superficial and deep veins.

The investigators will use a standard adult blood pressure cuff applied to the mid-upper arm statically inflated to 60mmHg to serve as a tourniquet.

The investigators will measure these parameters:

* AP diameter of the vein

* The cross-sectional area of the vein

* Width of the vein The investigators will measure veins from three different locations

* Anterior antecubital superficial vein

* Volar mid-forearm region deep vein

* Dorsal hand superficial vein

The investigators will make the measurements four times for each vein and participant:

1. Baseline: In this phase, the investigators will not apply any venodilation method

2. Tourniquet applied: The investigators will apply a blood pressure cuff tourniquet inflated to 60 mmHg pressure.

3. Tourniquet plus tapping directly over the vein manually

4. Tourniquet plus tapping directly over the vein with a massage device The investigators will change the 3rd and 4th items between two arms of the same participant. In other words, the investigators will do 1-2-3-4 for a left arm but 1-2-4-3 for the right arm. The investigators will assess whether the order affects the vein diameter by this change. The venous blood pressure cuff tourniquet will not be applied for more than 20 minutes continuously.

The investigators will take photos of the ultrasound vein visualizations and measure the diameter and cross-sectional area. This will have no PHI attached to the ultrasound images.

The investigators will take photos of the skin using a calibration ruler to assess the dilation of the visible veins externally. These photos will not reveal the subject's face or any personally identifiable images or information. After all study procedures are complete on the initial arm, study procedures will be repeated on the opposite arm.

Primary investigators will be responsible for collecting the data.

The investigators will not use the name or identifiable data when entering the data into the software. Rather than that, the investigators will code the participants (E.g., A01, B02). This data will be stored only in the departmental password-protected encrypted share drive. The survey and paperwork, including any participant data, will be stored at the locked drawers in investigators' offices

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
24
Inclusion Criteria
  • >18 years old,
  • Giving informed consent,
  • COVID-19 vaccinated (proof of vaccination must be shown)
Exclusion Criteria
  • COVID-19 unvaccinated,

  • Having unexplained COVID symptom(s) (This will be assessed by asking the ONE.UF screening questions):

    • Fever or chills
    • Cough
    • Fatigue
    • Muscle or body aches
    • Headache
    • New loss of taste or smell
    • Sore throat
    • Congestion or runny nose
    • Nausea or vomiting
    • Diarrhea
    • Close contact with a COVID-19 patient in 14 days

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Tourniquet plus manual tappingTourniquetThe investigators will apply a pressure cuff tourniquet inflated to 60 mmHg plus tapping directly over the vein manually.
Tourniquet plus device tappingDevice tappingThe investigators will apply a pressure cuff tourniquet inflated to 60 mmHg plus tapping directly over the vein with a massage device.
Tourniquet appliedTourniquetThe investigators will apply a blood pressure cuff tourniquet inflated to 60 mmHg pressure.
Tourniquet plus device tappingTourniquetThe investigators will apply a pressure cuff tourniquet inflated to 60 mmHg plus tapping directly over the vein with a massage device.
Tourniquet plus manual tappingManual TappingThe investigators will apply a pressure cuff tourniquet inflated to 60 mmHg plus tapping directly over the vein manually.
Primary Outcome Measures
NameTimeMethod
Change in standardized tapping with a device for PIVC2 hours

The primary outcome is to measure the vein diameters after manual and device tapping and detect the change from baseline in vein diameters.

Secondary Outcome Measures
NameTimeMethod
Change in the effect of tourniquet application2 hours

Secondary outcome is to measure the vein diameters before and after tourniquet application and detect the change from baseline in vein diameters.

Trial Locations

Locations (1)

University of Florida

🇺🇸

Gainesville, Florida, United States

© Copyright 2025. All Rights Reserved by MedPath