跳至主要内容
临床试验/ACTRN12612000013864
ACTRN12612000013864已完成未知

Stent Trial for Coarctaion of the Aorta to evaluate the safety and efficacy of the Large Diameter Advanta V12 Covered Stent for treatment of native and recurrent coartation of the aorta with primary endpoint being a significant reduction in the gradient across the coarctation at 12 months

Atrium Medical Corporation0 个研究点目标入组 70 人开始时间: 2012年1月4日最近更新:
适应症

试验速览

阶段
未知
状态
已完成
入组人数
70

研究概览

简要总结

暂无简介。

研究设计

研究类型
Interventional
分配方式
Non-randomised trial
主要目的
Treatment
盲法
Open (masking not used)

入排标准

年龄范围
Years 至 o limit(—)
性别
All

入选标准

  • Inclusion Criteria: - Patients with a presence of native or recurrent coarctation of the aorta as confirmed by blood pressure gradient, 2D-echocardiography with Doppler or angiography. - Subject weighs a minimum of 30 kg. - The peak pressure gradient is greater than or eqaul to 20 mmHg systolic blood pressure across the coarctation site. - Vessels at access site can accept a minimum size of 9 French for a 12 mm balloon and 11 French for a 14 and 16 mm balloon. - Coarctation can be successfully crossed with a guide wire, sheath and device. - Diameter of transverse arch distal to left subclavian artery is between 9.5 mm and 20 mm in diameter. - Subject is able and willing to adhere to all required follow-up visits and testing. - Subject is able and willing to adhere to the required follow-up medication regimen.

排除标准

  • Exclusion Criteria: - The physician is not able to access the coarctation with standard techniques. - Presence of other thoracic aortic arterial lesions or aneurysms requiring treatment within 30 days of the implant procedure. - Length of coarctation is greater than 45 mm in length. - Connective tissue and genetic disorders, including William, Marfan, Turner, Noonan syndrome. - The coarctation has adjacent, acute thrombus. - The coarctation was previously treated with a stent. - Proximity of the coarctation to an important side branch resulting in crossing of the side branch with the Large Diameter Advanta V12 Covered Stent device (e.g. jailing of the branch vessel). - Subject has a tubular graft, interposition graft, stent graft at or near the coarctation site that would be interfere with delivery, positioning, expansion or stabilization of the Large Diameter Advanta V12 Covered Stent - Subject has contrast agent hypersensitivity that cannot be adequately premedicated, has a hypersensitivity to stainless steel, ePTFE or has intolerance to antiplatelet, anticoagulant, or thrombolytic medications. - Bloodstream infection - Subject is pregnant or breastfeeding. - Subject has a co-morbid illness that may result in a life expectancy of less than 1 year. - The investigator deems the subject to be an inappropriate candidate for the study. - Subject is participating in an investigational study of a new drug, biologic or device at the time of study screening. NOTE: Subjects who are participating in the long term follow-up phase of a previously investigational and now approved product are not excluded by this criterion.

研究者

相似试验

Stent Trial for Coarctaion of the Aorta to evaluate... | 临床试验