跳至主要内容
临床试验/CTRI/2024/08/072752
CTRI/2024/08/072752尚未招募不适用

Comparative Evaluation Of the 3 Dimensional Implant Impression Accuracy Between Conventional and Digital Impression Using Two Different Intraoral Scanners:- An In Vivo Study

ITS Dental College Hospital And Research Centre1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2024年9月9日最近更新:

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
10
试验地点
1
主要终点
To comparatively evaluate 3 Dimensional implant impression accuracy between conventional and digital impression techniques

研究概览

简要总结

The study will be done to evaluate 3 dimensional implant impression accuracy between conventional and digital impression using two different intraoral scanners. The forthcoming in vivo study will be conducted in the department of Prosthodontics, Crown and Bridge , Maxillofacial Prosthodontics and Oral Implantology, I.T.S Dental College, Hospital and Research Centre, Greater Noida (U.P)   Patients of both genders aged from 18 years of age , who will be reporting to the department of Prosthodontics, Crown and Bridge , Maxillofacial Prosthodontics and Oral Implantology, I.T.S Dental College will serve as the source for the data collection.    A total of 10 patients with already placed implants will be the subjects for study.

**I.**Reference Model Fabrication

A Reference model will be made for each patient which will be serve as control for study. Reference model will be made by same procedure for each patient.   First, the healing abutments will be removed, and two square impression copings (4 mm diameter × 17 mm height;) will be hand tightened. The two impression copings will be splinted with autopolymerizing acrylic resin (Pattern Resin;).  To standardize the amount of splinting material for all instances, the dimension of the splinted assembly will be kept to 4 mm high and 2 mm wide; this amount of material could also prevent any distortion during the implant analog attaching procedure.   To verify the precise splinting procedure, the splinted assemblies will be sectioned through the middle of the index, and will be rejoined again with freshly mixed pattern resin material by the brush bead method. Then, the splinted assembly will be allowed to completely set prior to impression making. A periapical x-ray will be taken for every patient to confirm the complete seating before transferring it for impression making. After that, the splinted assembly will be removed, and analogs of the  same  size for all cases will be attached and hand tightened. They will then seated immediately in wet gypsum product.  To homogenize the impression making procedure, the gypsum powder and distilled water will used to produce each reference model.     After the stone will completely set, the splinted impression copings will be removed from the analogs. This fabricated model with the two analogs inside will be considered as the reference model (RM) in this study. For every participant, the RM will be first obtained with the same procedure as previously mentioned

**I.**Conventional implant impression technique and cast fabrication

**II.**Digital implant impression using two different intraoral scanners i.e. Aoralscan 3 (Shining 3D)   & CEREC Primescan (Dentsply sirona®).

Two scanners ( Primescan & Aoralscan 3 ) will be used for intraoral scanning & addition silicone impression material will be used for conventional impression technique. A master cast will            be poured with Types 4 gypsum product for conventional impression and will be scanned.

An Industrial scanner will be used for scanning  Reference model.

III. Measurements

All 3 STL files ( two intraoral scanner & one master model) will be superimposed with Reference model STL file and Interimplant distance deviation (2D) and coordinates (x, y, z),  will be assessed and compared among the two approaches.

All the data will be collected and Overall intergroup comparison among three groups will be done using One-way Anova ‘F’ test followed by Tukey’s post hoc test for pairwise intergroup                 comparison between each  groups.

研究设计

研究类型
Observational

入排标准

年龄范围
18.00 Year(s) 至 65.00 Year(s)(—)
性别
All

入选标准

  • 1.Two simultaneously placed implants 2.Healthy periodontium 3.Adequate mouth opening.

排除标准

  • 1.Patients with smoking or tobacco chewing habits 2.Patients with limited mouth opening 3.Patients not willing to participate in study.

结局指标

主要结局

To comparatively evaluate 3 Dimensional implant impression accuracy between conventional and digital impression techniques

时间窗: within 1 month of impression taking

次要结局

  • 1.To evaluate 3 Dimensional implant impression accuracy with conventional impression technique.

研究者

发起方
ITS Dental College Hospital And Research Centre
申办方类型
Research institution and hospital
责任方
Principal Investigator
主要研究者

Dr Rahul Ranjan

ITS Dental College Hospital And Research Centre, Greater Noida

研究点 (1)

Loading locations...

相似试验