Intrathoracic Esophagogastric Anastomosis After Robot Assisted Minimally Invasive Esophagectomy Using STRATAFIX
- Conditions
- Esophageal Cancer
- Interventions
- Device: Stratafix PGA Suture
- Registration Number
- NCT02609425
- Lead Sponsor
- Henry Ford Health System
- Brief Summary
Determine the safety and efficacy of novel suture in esophageal anastomosis. Specific Aims: 1) Determine the safety of using STRATAFIX suture in esophagogastric anastomosis by measuring anastomotic leak rate; and 2) Determine efficacy of STRATAFIX suture in esophagogastric anastomosis by measure anastomotic stricture rate.
- Detailed Description
The purpose of the proposed study is to demonstrate that a hand sewn anastomosis using STRATAFIX is safe and effective after minimally invasive esophagectomy and capture anastomotic leak and stricture rate after esophagectomy. If proven, one may reasonably conclude that STRATAFIX may be safely used in other less complex anastomoses and closures throughout the gastrointestinal tract. Furthermore, the work may promote the utilization of STRATAFIX for other applications, e.g. closure of the vaginal cuff after hysterectomy. The study is proposed to demonstrate the safety and efficacy of utilizing an absorbable running suture for completion of a hand swen intra thoracic esophago-gastric anastomosis during minimally invasive esophagectomy. There are many advantages to hand sewn anastomosis compared with stapled, e.g. EEA anastomosis. Two potential advantages are a lower leak rate and a lower stricture rate. Currently hand swen anastomosis is performed with interrupted suture of absorbable material. While effective, this technique requires multiple sutures, thus increasing operative time and material cost. Utilizing a running suture technique has the potential to reduce operative time and overall operative cost. Furthermore, it may lead to a reduction in postoperative morbidity by reducing anastomotic leak rate and structure formation. The hypothesis of the protocol is to evaluate the use of STRATAFIX in performing a hand swen intrathoracic anastomosis after minimally invasive esophagectomy is non inferior (and may be superior) to historical cases in which the anastomosis was completed using other types of suture material. Inclusion criteria: (1) All patients with esophageal cancer who are deemed candidates for minimally invasive robot assisted Ivor Lewis esophagogastrectomy. (2) Patients who provide written informed consent for the study. Exclusion criteria: Standard minimally invasive esophagectomy technique will be employed. (1) Creation of gastric conduit laparoscopically. (2) Robotic assisted esophageal mobilization through the right chest. (3) Robotic assisted intrathoracic anastomosis at or above the level of the azygous vein. (4) Barium swallow performed on post operative day 5-7 to assess anastomotic integrity. (5) Periodic clinical follow up on an outpatient basis to assess need for any interventions for anastomotic stricture.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 30
- All patients with esophageal cancer who are deemed candidates for minimally invasive robot assisted Ivor Lewis esophagogastrostomy.
- Patients who provide written informed consent for the study.
- Any patient with esophageal cancer who is not deemed a surgical candidate or who is not deemed a candidate for the Ivor Lewis technique of esophagectomy (with intrathoracic anastomosis).
- Any patient less than 18 years of age
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description STRATAFIX Stratafix PGA Suture Anastomosis of esophagus to stomach
- Primary Outcome Measures
Name Time Method Anastomotic Leak Rate After Esophagectomy 5-7 Days to assess anastomotic integrity Analysis specific to anastomosis leak will be analyzed and compared with historically published results to determine whether Stratafix suture is appropriate in this application.
- Secondary Outcome Measures
Name Time Method Anastomotic Stricture Rate After Esophagectomy 5-7 days to assess anastomotic integrity Analysis specific to anastomosis stricture will be analyzed and compared with historically published results to determine whether Stratafix suture is appropriate in this application.
Trial Locations
- Locations (1)
Henry Ford Health System
🇺🇸Detroit, Michigan, United States