跳至主要内容
临床试验/NCT03674710
NCT03674710Unknown不适用

A Multi-center, Prospective, Single-blind, Controlled Trial Comparing Suction Technique, Slow-pull Method and Wet Suction Technique on Specimen Quality and Diagnostic Accuracy in Endoscopic Ultrasound-guided Fine-needle Aspiration

Shanghai Zhongshan Hospital4 个研究点 分布在 1 个国家目标入组 300 人开始时间: 2017年12月18日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
300
试验地点
4
主要终点
Diagnostic yield of standard suction technique

研究概览

简要总结

The aim of this study is to compare endoscopic ultrasound guided-fine needle aspiration (EUS-FNA) with a standard 22-gauge needle using "standard suction", "slow-pull" and "wet suction" for thoracic/abdominal solid/solid-cystic lesions. Investigators intend to compare the effectiveness and safety of the three methods in order to discover the optimized technique for obtaining diagnostic material and making accurate diagnosis.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • In-patients and out-patients between the age of 18years and 80 years with thoracic/abdominal solid/solid-cystic lesions for EUS-FNA.

排除标准

  • Uncorrectable coagulopathy (INR > 1.5)
  • Uncorrectable thrombocytopenia (platelet < 50,000)
  • Cystic lesions
  • Inaccessible lesions to EUS
  • Contraindications for conscious sedation
  • Uncooperative patients
  • Refusal to consent form

结局指标

主要结局

Diagnostic yield of standard suction technique

时间窗: 1 year

A positive diagnosis of malignancy by an EUS biopsy specimen is accepted as a true positive. A benign diagnosis is confirmed by surgical tissue samples when available or clinical follow-up after 1 year.

Specimen quality score of wet suction

时间窗: Immediate

EUS-FNA obtained specimen is scored as follows: 1) blood contamination: 0 for severe, 1 for moderate, 2 for few; 2) tissue structure: 0 for none, 1 for 1-2 structures seen, 2 for more than 3 structures seen; 3) cell quantity: 0 for \<10/HPF, 1 for \<50/HPF, 2 for \>50/HPF; 4) diagnosability: 0 for hard to diagnose, 1 for suspicious diagnose, 2 for definite diagnosis.

Diagnostic yield of slow-pull technique

时间窗: 1 year

A positive diagnosis of malignancy by an EUS biopsy specimen is accepted as a true positive. A benign diagnosis is confirmed by surgical tissue samples when available or clinical follow-up after 1 year.

Specimen quality score of standard suction

时间窗: Immediate

EUS-FNA obtained specimen is scored as follows: 1) blood contamination: 0 for severe, 1 for moderate, 2 for few; 2) tissue structure: 0 for none, 1 for 1-2 structures seen, 2 for more than 3 structures seen; 3) cell quantity: 0 for \<10/High power field(HPF), 1 for \<50/HPF, 2 for \>50/HPF; 4) diagnosability: 0 for hard to diagnose, 1 for suspicious diagnose, 2 for definite diagnosis.

Diagnostic yield of wet suction technique

时间窗: 1 year

A positive diagnosis of malignancy by an EUS biopsy specimen is accepted as a true positive. A benign diagnosis is confirmed by surgical tissue samples when available or clinical follow-up after 1 year.

Specimen quality score of slow-pull

时间窗: Immediate

EUS-FNA obtained specimen is scored as follows: 1) blood contamination: 0 for severe, 1 for moderate, 2 for few; 2) tissue structure: 0 for none, 1 for 1-2 structures seen, 2 for more than 3 structures seen; 3) cell quantity: 0 for \<10/HPF, 1 for \<50/HPF, 2 for \>50/HPF; 4) diagnosability: 0 for hard to diagnose, 1 for suspicious diagnose, 2 for definite diagnosis.

次要结局

  • Adverse event(1 week)

研究者

发起方
Shanghai Zhongshan Hospital
申办方类型
Other
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验

A Multi-center, Prospective, Single-blind,... | 临床试验