Skip to main content
Clinical Trials/NCT02440919
NCT02440919Active, not recruitingNot Applicable

Effects of Low Oxygen Supplementation and Ventilator Hyperinflation in the Endotracheal Suction of Mechanically Ventilated Patients

Universidade Federal de Sao Carlos2 sites in 1 country78 target enrollmentStarted: June 1, 2013Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Active, not recruiting
Sponsor
Enrollment
78
Locations
2
Primary Endpoint
Oxygen (SpO2) and Ventilation (ETCO2) measures

Study Overview

Brief Summary

This is a double crossover study where all patients are randomly allocated to one of two treatment sequences associated with endotracheal aspiration.The first treatment (A) uses two suctioning methods for each patient: one involving hyperoxygenation with administration of 100% oxygen 1 minute before and after suction (intervention I), and the other hyperoxygenation with oxygen supply to 20% above basal offer (Intervention II) in the same way.The second treatment (B) uses a technique of hyperinflation with the mechanical ventilator (PEEP-ZEEP) associated with hyperoxygenation. The intervention I, uses PEEP-ZEEP offering 20% above basal oxygenation and intervention II uses the PEEP-ZEEP with basal oxygen supply in the same way.

All subjects were randomly allocated using sealed envelopes to a treatment sequence A or B on Day 1. Patients received two treatments, at least four hours apart. The first treatment is in the morning and the alternate treatment is performed in the afternoon. On Day 2 the order of the treatments was reversed using the same patient position sequence.The interventions I and II are performed at least 4 hours apart to minimize any carryover effect.

Detailed Description

Endotracheal suction must be carried out only through precise indication, because it is associated with undesirable effects on the hemodynamic parameters, ventilation, oxygenation and respiratory mechanics.

The hyperoxygenation is one of the methods of prevention of hypoxemia induced by tracheal suction procedure and have been proposed for its efficiency. Another method is the hyperinflation with the mechanical ventilator. Ventilator hyperinflation improves oxygenation, mobilizes the bronchial secretion excess and re-expand the lung collapsed areas.

The PEEP-ZEEP is a ventilator hyperinflation technique, described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to ZEEP (0 centimeters of water (cmH2O)).

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Crossover
Primary Purpose
Treatment
Masking
Single (Participant)

Eligibility Criteria

Ages
18 Years to 95 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Mechanical ventilation for more than 12h
  • Hemodynamic stability
  • Presence of indication criteria of endotracheal aspiration procedure

Exclusion Criteria

  • High doses of vasopressor amines amines and/or severe arrhythmias
  • Hemoglobin < 7 g/dL
  • FiO2 ≥ 0.6
  • PEEP ≥ 10 cmH2O
  • Conditions: rib fractures, chest drain, severe bronchospasm, pneumothorax not drained and tracheostomy
  • Contraindications of ventilator hyperinflation(PEEP-ZEEP): intracranial pressure > 10 mmHg, bleeding disorders, accented degrees of gastroesophageal reflux and bullous lung disease.

Outcomes

Primary Outcomes

Oxygen (SpO2) and Ventilation (ETCO2) measures

Time Frame: Endotracheal suctioning is carried out according each protocol. Oxygen (SpO2) and ventilation (ETCO2) measures are performed before and after supply oxygen given for 1 minute, 60 seconds after each suctioning, immediately after and 30 minutes the end.

Oxygenation is evaluated by peripheral oxygen saturation (SpO2), measured by a respiratory monitor (DX-2021™ or DX-2023™- Dixtal™. The Impact on oxygenation was detecting hypoxemia with SpO2 values below 90%. Ventilation is evaluated by end-tidal carbon dioxide measured by carbon dioxide sensor (CAPNOSTAT CO2 Sensor, Novametrix Medical Systems Inc.) inserted into the mechanical ventilator circuit Dixtal 3012™ - Dixtal™. The impact on ventilation was detecting hypoventilation with values exceeding 50 mmHg.

Secondary Outcomes

  • Respiratory mechanic measures(Endotracheal suctioning is carried out according each protocol. Baseline Respiratory mechanic measures are performed before suctioning, immediately after and 30 minutes the end.)
  • Volumetric capnography measures(Endotracheal suctioning is carried out according each protocol. Baseline Volumetric capnography measures are performed before suctioning, immediately after and 30 minutes the end.)

Investigators

Sponsor
Universidade Federal de Sao Carlos
Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Jacqueline R F Vianna

Master's degree

Universidade Federal de Sao Carlos

Study Sites (2)

Loading locations...

Similar Trials