A Study on the Effectiveness of the Application of an Artificial Intelligence Algorithm for Calibrating PPG With ECG to Improve the Accuracy of Atrial Fibrillation Burden Estimation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 1,054
- 试验地点
- 1
- 主要终点
- Automatically analyze the W-PPG data and the W-PPG data calibrated by W-ECG.
研究概览
简要总结
Use the ECG watch to collect W-PPG and W-ECG data. Through artificial intelligence algorithms, compare the W-PPG data collected by the ECG watch and the W-PPG data calibrated by the W-ECG data of the ECG watch with the P-ECG data manually annotated after being collected by the ECG recorder. Then evaluate the effectiveness of the calibrated algorithm in improving the accuracy of estimating atrial fibrillation burden.
详细描述
After the subjects are fully informed and sign the informed consent form, they will be asked to wear the "ECG recorder" and the "ECG watch" simultaneously to collect P-ECG data as well as W-PPG and W-ECG data respectively. The collection period is from the patient's admission to the time before the patient's surgery. The collected data will be analyzed by the "Smart-AF" of Xinjikang Company. The W-PPG data collected by the ECG watch and the W-PPG data calibrated by the W-ECG data of the ECG watch will be compared with the P-ECG data that has been manually annotated after being collected by the ECG recorder. The differences in identifying atrial fibrillation and in the statistics of atrial fibrillation burden between the W-PPG data of atrial fibrillation patients and the P-ECG data as well as the W-PPG and P-ECG data calibrated by comparison with the W-ECG data will be compared.
ECG Watch ECG Monitoring Method:
- Positive Alert: W-PPG detects atrial fibrillation and prompts measurement of W-ECG When W-PPG detects atrial fibrillation, the data is uploaded to the server for confirmation. If the server detects atrial fibrillation, it triggers a vibration message to prompt the measurement of W-ECG. If a valid W-ECG measurement is not completed within 5 minutes after the message alert, a vibration reminder is triggered again, with a maximum of two reminders per trigger point. When the daily reminder count reaches 10, no further reminders will be given; for the first 5 reminders, each pair of reminders must be at least 20 minutes apart, and for the last 5 reminders, each pair must be at least 40 minutes apart.
- Periodic Reminder: Scheduled reminders for W-ECG measurement Vibration reminders are triggered at fixed times: 09:00, 10:30, 11:30, 13:00, 14:00, 15:30, 17:00, 18:00, 19:00, 20:30. If a 60-second W-ECG measurement is not completed within 5 minutes after each trigger, a vibration reminder is triggered again, with a maximum of two vibration reminders per trigger point.
- Voluntary Measurement: Active measurement of W-ECG During the period when the subject is wearing the watch, they can voluntarily measure W-ECG.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Automatically analyze the W-PPG data and the W-PPG data calibrated by W-ECG.
时间窗: One day
Automatically analyze the W-PPG data and the W-PPG data calibrated by W-ECG through the "Smart-AF" of Xinjikang Company, and then compare the analyzed results with the P-ECG results manually annotated and proofread.
次要结局
- Automatically analyze the W-PPG data and the W-PPG data calibrated by W-ECG.(One day)
