Sperimentazione Clinica Del Sistema INSIDE - Innovative SolutIons for DosimEtry in Hadrontherapy - Per il Monitoraggio Del Trattamento in Adroterapia

CNAO National Center of Oncological Hadrontherapy1 site in 1 country40 target enrollmentJuly 16, 2019

Overview

Phase
N/A
Intervention
Not specified
Conditions
Particle Therapy
Sponsor
CNAO National Center of Oncological Hadrontherapy
Enrollment
40
Locations
1
Primary Endpoint
particles ranges
Status
Recruiting
Last Updated
8 months ago

Overview

Brief Summary

The study aim is to test the clinical feasibility and effectiveness of an online qualitative monitoring device named INSIDE system during hadrontherapy treatments.

This instrumentation is composed by detectors able to acquire secondary signals generated by the interaction of the primary beam with human tissues. From these measurements performed during irradiation, the INSIDE system estimates the particle beam range inside the patient's body and check the compliance of the ongoing treatment with the clinical prescription, with the aim to optimize the delivered dose.

The study aims to longitudinally monitor patients treated with hadrontherapy at the Italian National Centre of Oncological Hadrontherapy (CNAO) in Pavia in order to:

  • evaluate the stability of the INSIDE system response and the significance of the monitoring measurement;
  • study the clinical tolerances between ongoing and prescribed treatments within which the differences in particle range are not clinically relevant;
  • assess what impact an instrument such as the INSIDE system can have on the clinical routine;
  • evaluate the benefits of such a monitoring system with respect to treatment planning constraints.

Detailed Description

A treatment monitoring instrumentation is highly demanded to maximize the benefits of hadrontherapy from the increased conformation of the released dose to the tumor volume with respect to the conventional radiotherapy. Since almost all the energy of the charged particles is deposited in the end of their track (Bragg Peak region), the verification of the particle range by experimental measurements, performed during treatment delivery, can help to increase the therapy effectiveness while better sparing healthy tissues. The INSIDE system is an innovative bi-modal instrumentation consisting of an in-beam Positron Emission Tomography (PET) scanner, to detect annihilation photons coming from positron isotope emitters, and a Dose Profiler to collect signals from charged particles emitted during treatment (e.g. protons in the case of carbon ion treatments). The in-beam PET scanner is composed by two opposite panels of detectors placed above and below the patient bed, respectively. The Dose Profiler is positioned above the patient with an angle of 60°, forwardly with respect to the beam direction. The INSIDE system is a passive instrumentation, i.e. no additional dose has to be released to the patient for particle range verification. The INSIDE detectors are mounted on a mobile support and, immediately before the treatment delivery, they will be placed around the patient in the acquisition position, thanks to a dedicated hooking system designed to guarantee the maximum precision and accuracy in the particle range verification. The INSIDE system mechanics is compatible with multi fields irradiation of patients affected by pathologies of Head-and-Neck and Brain districts. In the clinical trial, patients affected by four selected pathologies will be included: meningioma and nasopharynx cancers treated with proton beams, Adenoid Cystic Carcinoma (ACC) and clival chordoma treated with carbon ion beams. These were chosen in order to study both projectile particles available at the CNAO centre (i.e., protons and carbon ions), and target specific pathologies which should most benefit from the range monitoring provided by the INSIDE system. Among them are cancers for which an early response is commonly observed and tumors which are located near cavities that can be filled with either water-like material (such as cancerous mass and inflamed tissues) or air. The patients will undergo a longitudinal protocol of measurements in order to verify the agreement between the ongoing treatment and the prescription throughout the complete treatment period (lasting in average about 4-6 weeks for the selected pathologies).

Registry
clinicaltrials.gov
Start Date
July 16, 2019
End Date
December 31, 2025
Last Updated
8 months ago
Study Type
Observational
Sex
All

Investigators

Sponsor
CNAO National Center of Oncological Hadrontherapy
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • patients treated at CNAO with protons or carbon ions with horizontal beam line.
  • meningioma, ACC, skull base (clivus) chordoma, squamous cellular rhinopharynx carcinoma
  • full compatibility of the INSIDE monitoring system with all beam delivery devices in the established irradiating position
  • all emergency procedures are possible notwithstanding INSIDE system positioned.
  • signed written informed consent by patient.
  • Exclusion Criteria
  • missing informed consent
  • not affected by one of the selected pathologies
  • failure of pre-treatment compatibility technical assessment
  • failure of pre-treatment emergency procedures check

Exclusion Criteria

  • Not provided

Outcomes

Primary Outcomes

particles ranges

Time Frame: average of 5 weeks (as a treatment duration)

evaluate the quality of treatments in term of data collection and of particles range evaluated with PET scanner and Monte Carlo simulations

particles ranges for each pathology considered

Time Frame: 4 months

statistical analysis to assess the evaluations of treatment