STENTYS Self-expanding Versus Balloon-expandable Stent in Acute Myocardial Infarction (AMI)
- Conditions
- STEMI
- Interventions
- Device: Stentys coronary stentDevice: Balloon-expandable stent
- Registration Number
- NCT01008085
- Lead Sponsor
- Stentys
- Brief Summary
Study hypothesis: the Stentys self-expandable Stent results into a better alignment of the struts to the vessel wall than a balloon-expandable stent within a few days after the procedure in acute myocardial infarction patients.
- Detailed Description
Stent strut malapposition and stent underexpansion are a common phenomenon in AMI as a result of the changing anatomy after an AMI has occurred (thrombus dissolution, resolution of spasm) with the traditional balloon-expandable stent treatment. A self-expanding stent might lead to better stent strut apposition as it follows the contours of the vessel wall due to its self-expanding properties. This might result into better long term clinical outcomes like lower thrombosis rates.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 80
-
Subject 18 years old.
-
Acute Myocardial Infarction defined as presence of at least two of the three items below:
- Detection of rise of cardiac biomarkers with a least one value above the 99th percentile of the upper reference limit (URL)
- Symptoms of ischaemia (chest pain) >20 minutes
- ECG changes indicative of new ischaemia: new ST-T changes (ST deviation ≥0.2mV precordial leads and/or ≥0.1mV limb leads) or new LBBB)
-
Reperfusion expected to be achieved within 12 hours from the onset of symptoms
-
Subject understands the nature of the procedure and provides written informed consent prior to the catheterization procedure.
-
Subject is willing to comply with specified follow-up evaluation and can be contacted by telephone.
-
Acceptable candidate for coronary artery bypass graft (CABG) surgery.
-
Male or non-pregnant female subject.
Angiographic Inclusion Criteria:
- Reference vessel diameter >2.5mm and <4.0mm by visual estimate.
- Target lesion <30mm in length by visual estimate
- Currently enrolled in another investigational device or drug study that has not completed the primary endpoint or that clinically interferes with the current study endpoints.
- Coronary or cardiac intervention or major surgery of any kind within 30 days prior to the procedure.
- Target vessel supplied by by-pass vessel
- Patients on anticoagulation therapy (Coumadin)
- Patient received thrombolytic therapy.
- Myocardial infarction due to stent thrombosis, or infarct lesion at the side of a previously implanted stent
- Cardiogenic shock
- Any previous stent placement within 10mm (proximal or distal) of the target lesion.
- Co-morbid condition(s) that could limit the subject's ability to participate in the study or to comply with follow-up requirements, or impact the scientific integrity of the study.
- Concurrent medical condition with a life expectancy of less than 6 months.
- Left ventricular ejection fraction (LVEF) <30% at the most recent evaluation.
- Cerebrovascular accident or transient ischemic attack in the last 6 months.
- Known hypersensitivity or contraindication to aspirin, heparin or bivalirudin, clopidogrel or ticlopidine, cobalt, nickel, or sensitivity to contrast media, which cannot be adequately pre-medicated.
- Known serum creatinine level >2.5mg/dl or presence or history of renal failure
Angiographic Exclusion Criteria:
- Unprotected left main coronary artery disease (obstruction greater than 50% in the left main coronary artery that is not protected by at least one non-obstructed bypass graft to the left anterior descending (LAD) or left circumflex (LCX) artery or a branch thereof).
- Target vessel is excessively tortuous (two bends >90˚ to reach the target lesion).
- Lesion location that is aorto-ostial or within 5mm of the origin of the LAD or LCX.
- Target lesion is severely calcified.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Self-expanding stent Stentys coronary stent Stentys stent Balloon-expandable stent Balloon-expandable stent VISION/Driver
- Primary Outcome Measures
Name Time Method Stent strut apposition measured by optical coherence tomography (OCT) 3 days after procedure
- Secondary Outcome Measures
Name Time Method Stent thrombosis 30 days and 6 months
Trial Locations
- Locations (1)
C. Spaulding
🇫🇷Paris, France