The Impact of Clinical Decision Support (CDS) for Radiology: A Randomized Control Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 3,511
- 试验地点
- 2
- 主要终点
- number of scans ordered that would be subject to the CDS best practice alert
研究概览
简要总结
The goal of the study is to determine whether clinical decision support (CDS) for radiology affects the number, type, or appropriateness of targeted high-cost radiology imaging orders (i.e. magnetic resonance (MR), computed tomography (CT), nuclear medicine (NM) and Positron Emission Tomography (PET) scans). The CDS will be delivered to physicians in the Aurora Health Care system. It will be delivered in Epic, an industry-standard electronic medical record software, through ACR Select, which is a leading decision support tool based on the American College of Radiology (ACR) Appropriateness Criteria (see http://www.acr.org/Quality-Safety/Appropriateness-Criteria). The ACR Select tool rates imaging orders on a scale of 1-9 with 1-3 labelled as 'usually not appropriate', 4-6 'May be appropriate', and 7-9 'usually appropriate'.
详细描述
With healthcare spending accounting for almost one-fifth of the U.S. economy and an even larger share of public sector budgets, there is substantial interest in innovations in healthcare delivery that can reduce the "over use" of resources that have no or low value to patients. As a result, there is a key need for rigorous evidence on scalable interventions aimed at improving the efficiency of the U.S. healthcare sector in general, and in the public sector in particular, which accounts for $1.25 trillion in annual healthcare spending.
In particular, there is widespread concern in both the medical profession and the public sector of the cost and health risks of "over-scanning". Estimates suggest that as many as 30% of imaging in the U.S. are unnecessary. Medicare direct spending on "high-cost" scans (e.g. MRs and CTs) was about $10 billion in 2012, or about 2% of total Medicare costs ; the indirect costs are likely considerably greater, since imaging often triggers additional follow up care. It is also estimated that about 2 percent of cancers in the U.S. are due to CT use.
Reflecting this concern, starting in 2018 Medicare will no longer reimburse for high-cost scans unless ordered using an "acceptable" Clinical Decision Support (CDS) system. Despite this upcoming policy change, the investigators know of no large-scale randomized trials on the impact of CDS for imaging.
The intervention in this study provides Clinical Decision Support (CDS) for targeted high-cost radiology orders, (MR, CT, NM, and PET scans), to healthcare providers treating patients in settings affiliated with the Aurora Health Care system headquartered in Wisconsin. CDS is a tool embedded in an order entry system that provides information and guidance to providers on whether their intended order is "appropriate" and whether there are more highly recommended alternatives. The randomization is at the provider level: half will receive the CDS, while the remaining half of providers in the study will serve as the control group.
The CDS will be delivered through the order-entry software, Epic, through ACR Select software, which is a leading decision support tool based on the American College of Radiology (ACR) Appropriateness Criteria.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Health Services Research
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Medical provider actively employed at Aurora with a valid Epic log-in.
- •Is a Medical Doctor (MD), Doctors of Osteopathic Medicine (DO), podiatrist (DPM), nurse practitioner (NP), physician assistant (PA), or certified nurse midwife (CNM)
- •Has imaging order permissions at Aurora Health Care.
- •Has at least one high- or low-cost imaging order in the year from November 1, 2015 to November 1, 2016 or is medical resident who joined Aurora since that time.
排除标准
- •Opted out of the study prior to November 24, 2016
结局指标
主要结局
number of scans ordered that would be subject to the CDS best practice alert
时间窗: first 365 days after CDS is turned on for the treatment group
Scans where the CDS would be triggered based on the criteria listed in the intervention description
次要结局
- Number of scans ordered that would be subject to the CDS best practice alert and that ACR Select rates 1-3 ("usually not appropriate")(first 365 days after CDS is turned on for the treatment group)
- Number of scans ordered that would be subject to the CDS best practice alert and that ACR Select rates 4-6 ("may be appropriate")(first 365 days after CDS is turned on for the treatment group)
- Number of high-cost scans (CT, MR, NM and PET) ordered(first 365 days after CDS is turned on for the treatment group)