跳至主要内容
临床试验/NCT06378255
NCT06378255
已完成
不适用

Clinical Evaluation of Polycation-based New Dental Desensitizer on Dentin Hypersensitivity

Peking University Hospital of Stomatology1 个研究点 分布在 1 个国家目标入组 40 人2024年3月20日

概览

阶段
不适用
干预措施
Polycation-based new dentinal desensitizer
疾病 / 适应症
Dentin Sensitivity
发起方
Peking University Hospital of Stomatology
入组人数
40
试验地点
1
主要终点
Improvement of dentin sensitivity induced by probe pressure stimulation
状态
已完成
最后更新
2个月前

概览

简要总结

Evaluate the safety and clinical efficacy of new dental desensitizers in the treatment of dentin sensitivity, including the relief of sensitivity symptoms and the duration of efficacy.

详细描述

This is a randomized, single-blind and controlled study to include 40 patients with dentin sensitivity. The study will be a randomized controlled trial with split mouth control, with two quadrants of the same patient as test and control groups, the test group being the group using the new desensitizer and the control group being the group with the clinically used desensitizer (Gruma desensitizer). Improvement in dentin sensitivity symptoms was the primary outcome indicator observed. Dentin sensitivity was assessed by evaluating the reduction in dentin sensitivity VAS scores at immediately, 1 month, 3 months, and 6 months points after the desensitization treatment, and by evaluating the subjects' self-reported relief of sensitivity. Safety was assessed by evaluating appliance defects and adverse events at the immediately,1-, 3-, and 6-months points after the desensitization treatment.

注册库
clinicaltrials.gov
开始日期
2024年3月20日
结束日期
2025年8月11日
最后更新
2个月前
研究类型
Interventional
研究设计
Parallel
性别
All

研究者

入排标准

入选标准

  • Dentin Hypersensitivity, with Vas score≥4 points and the normal pulp viability
  • dentin-sensitive tooth in at least 2 different quadrants of the mouth (neck enamel dentin exposure or maxillofacial abrasion within the middle layer of dentin).
  • in good overall health
  • participants informed consent.

排除标准

  • gastroesophageal reflux
  • Dental caries, wedge defects, crowns or large fillings.
  • Received dentin sensitivity desensitization treatment or used desensitization mouthwash within 1 month.
  • Received systematic periodontal therapy or periodontal surgery within 3 months, ongoing orthodontic treatment, and medical treatment, including long-term use of anti-inflammatory, analgesic, and psychotropic medications.
  • Pregnancy or breastfeeding.
  • Participated in other clinical trials in the past 3 months.

研究组 & 干预措施

Polycation-based new dentinal desensitizer

Use a cotton ball or brush to apply a small amount of desensitizing agent to the sensitive tooth surface for about 1 minute and wait for 2 minutes. Excess gel is then wiped off the surface.

干预措施: Polycation-based new dentinal desensitizer

GLUMA desensitizer

Use according to instructions

干预措施: GLUMA desensitizer

结局指标

主要结局

Improvement of dentin sensitivity induced by probe pressure stimulation

时间窗: At Baseline and 10 minutes, 1 month, 3 months, 6 months after desensitization treatment

The severity of dentin sensitivity is assessed using visual analogue scale (VAS) with numbers 0-10 by participants after probe pressure stimulation. Beforehand, the participants were informed that the 10 cm VAS would be used to assess their pain sensitivity, with 0 indicating no pain and 10 indicating the worst pain. Lower scores on the VAS indicate lower sensitivity. Dentin sensitivity was considered to have improved if the visual pain scale (F-VAS) score decreased by 2 or more points from baseline.

次要结局

  • Improvement of dentin sensitivity induced by air temperature stimulation(At Baseline and 10 minutes, 1 month, 3 months, 6 months after desensitization treatment)

研究点 (1)

Loading locations...

相似试验