Evaluating the Safety and Effectiveness of 5G Cloud Follow-up for Cardiovascular Implantable Electronic Devices: a Prospective, Paired, Self-controlled, Non-inferiority, Multicenter Clinical Trial
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 688
- 试验地点
- 2
- 主要终点
- Parameter Measurement Consistency
研究概览
简要总结
Objective: This clinical study employs a prospective, paired, self-controlled, non-inferiority, multicenter research design to assess the safety and efficacy of utilizing 5G cloud follow-up for CIED in parameters monitoring and remote programming post-implantation.
Participants will:
undergo regular clinic follow-up visits in accordance with the guidelines undergo routine in-office follow-up and 5G cloud follow-up during each regular clinic visit
详细描述
Background: Cardiovascular implantable electronic devices (CIED) include pacemakers, implantable cardioverter defibrillators (ICD), cardiac resynchronization therapy (CRT) pacemakers and defibrillators, implantable cardiac event recorders (ICM), and implantable cardiovascular monitors. They are mainly used for the diagnosis, monitoring, and treatment of bradycardia, tachycardia, and heart failure (HF). There are currently two main methods of follow-up: routine in-office follow-up and remote monitoring (RM). Routine in-office follow-up is the most commonly used method in China, whereby professional doctors and/or manufacturer engineers conduct follow-ups under the guidance of physicians. Remote monitoring (RM) allows patients to be remotely monitored at home or elsewhere when a communication network is available, receiving periodic alerts related to the patient. Remote monitoring (RM) can provide timely and accurate CIED data and information, promptly alerting clinical doctors to any issues. However, a drawback is that patients still need to visit the hospital for device parameter adjustments, so it only partially fulfills the functions of routine in-office follow-up. Of note, in the past three years, some domestic clinical centers in China have begun exploring the application of 5G cloud follow-up remote programming (5G Cloud Follow Up) in various patient follow-up scenarios. With the comprehensive deployment of 5G networks in China, central hospitals with specialized device programmers can establish one-to-one or one-to-many regional collaborative cloud follow-up systems with primary hospitals lacking follow-up technician through 5G networks. CIED patients only need to visit nearby primary hospitals to complete regular device follow-ups. Currently, excellent research results have been obtained in the quality control of the CIED follow-ups of a single provincial medical consortium system mainly consisting of major implantation centers. However, there is still a lack of verification results for 5G cloud follow-up remote programming in a medical consortium (MC) model covering various administrative regions in China and different levels of primary hospitals. This study will compare the safety and effectiveness of using 5G cloud follow-up remote programming in different administrative regions and levels of primary hospitals in China with routine in-office follow-ups.
Objective
This clinical study employs a prospective, paired, self-controlled, non-inferiority, multicenter research design to assess the safety and efficacy of utilizing 5G cloud follow-up for CIED in parameters monitoring and remote programming post-implantation.
Participants will:
undergo regular clinic follow-up visits in accordance with the guidelines undergo routine in-office follow-up and 5G cloud follow-up during each regular clinic visit
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Health Services Research
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age ≥ 18 years, gender unspecified;
- •Patients who have not undergone their first clinic follow-up after the implantation of cardiovascular implantable electronic devices (CIED); Note: In this study, CIED includes pacemakers, implantable cardioverter defibrillators (ICD), cardiac resynchronization therapy pacemakers (CRT-P) and defibrillators (CRT-D), excluding implantable cardiac event recorders (ICM) and implantable cardiovascular monitors.
- •Willing to participate in this clinical study and have signed the informed consent form in writing.
排除标准
- •Exclusion Criteria:
- •If meeting any of the following, the individual cannot be included:
- •Life expectancy < 1 year.
- •Inability to cooperate with treatment or follow-up, such as having mental illness.
- •Participated in other clinical studies within 30 days before enrollment. Other situations that the researcher deems unsuitable for inclusion.
研究组 & 干预措施
5G cloud follow-up & Routine follow-up
CIED patients undergo both 5G cloud follow-up and routine in-office follow-up during each visit.
干预措施: Routine Management (Other)
5G cloud follow-up & Routine follow-up
CIED patients undergo both 5G cloud follow-up and routine in-office follow-up during each visit.
干预措施: 5G Cloud Follow-up (Device)
结局指标
主要结局
Parameter Measurement Consistency
时间窗: through study completion, an average of 1 year
Subjects underwent in-office follow-up and 5G cloud follow-up to test battery parameters (battery voltage, battery current, and magnet frequency) and lead parameters (amplitude, pacing threshold, and impedance) in the immediate postoperative period, prior to discharge from the hospital, and within 1 month of implantation, within 1 to 3 months of implantation, at 6 months of implantation, and at 12 months of implantation, respectively. The consistency of each parameter measured at both follow-up modalities was analyzed at the end of the trial by regression fitting equations and Pearson correlation coefficients.
次要结局
- Parameter Measurement Time(through study completion, an average of 1 year)
- Program Completion Rate(through study completion, an average of 1 year)
- adverse events(through study completion, an average of 1 year)
研究者
Lin Cai
Professor of Department of Cardiology
The Third People's Hospital of Chengdu