Positron Emission Tomography Imaging Using Copper Cu 64 TP3805 in Patients With Breast Cancer
- Conditions
- Breast Carcinoma
- Interventions
- Device: Positron Emission MammographyDevice: Positron Emission TomographyRadiation: Fludeoxyglucose F-18
- Registration Number
- NCT02810873
- Brief Summary
This clinical trial studies positron emission tomography imaging in using copper Cu 64 TP3805in patients with breast cancer. Diagnostic procedures, such as positron emission tomography (PET) and positron emission mammography (PEM) scan, using Cu-64-TP3805 may help doctors find and diagnose breast cancer.
- Detailed Description
OBJECTIVES:
I. The study's primary goal is to assess the ability of Cu-64-TP3805 (copper Cu 64 TP3805) to detect primary breast lesions as determined by the F-18-FDG (fludeoxyglucose F 18) scan.
II. The study's second goal is to determine the ability of Cu-64-TP3805 to detect primary breast lesions as determined by histology (sensitivity).
III. The study's third goal is to determine the ability of Cu-64-TP3805 to detect metastatic lesions as identified by the F-18-FDG whole-body scan.
OUTLINE: This is a dose-finding 2-stage study.
STAGE I: Patients with a positive biopsy and abnormal (positive) fludeoxyglucose F18-labeled PET whole-body scan undergo a whole-body copper Cu 64 TP3805-labeled PET scan.
STAGE II: Patients with a positive biopsy, but no fludeoxyglucose F18 scan undergo a breast fludeoxyglucose F18-labeled PEM scan followed by a breast copper Cu 64 TP3805-labeled PEM scan.
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- Female
- Target Recruitment
- 19
- Female
- Breast cancer shown with abnormal mammogram and histology verification (stage-1 patients will also need to have a positive F-18-FDG whole-body scan)
- Tumor mass of 1 cm or larger, as determined by mammography, ultrasound, or magnetic resonance imaging (MRI)
- Signed informed consent form approved by the institutional review board (IRB)
- Pregnant or lactating female
- Patient with asthma
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description No F-18-FDG Scan Copper Cu 64 TP3805 STAGE II: Patients with a positive biopsy, but no fludeoxyglucose F18 scan undergo a breast fludeoxyglucose F18-labeled PEM Positron Emission Mammography scan followed by a breast copper Cu 64 TP3805-labeled PEM scan. F-18-FDG Whole body Scan Copper Cu 64 TP3805 STAGE I: Patients with a positive biopsy and abnormal (positive) fludeoxyglucose F18-labeled PET whole-body scan undergo a whole-body copper Cu 64 TP3805-labeled PET scan. F-18-FDG Whole body Scan Positron Emission Mammography STAGE I: Patients with a positive biopsy and abnormal (positive) fludeoxyglucose F18-labeled PET whole-body scan undergo a whole-body copper Cu 64 TP3805-labeled PET scan. F-18-FDG Whole body Scan Fludeoxyglucose F-18 STAGE I: Patients with a positive biopsy and abnormal (positive) fludeoxyglucose F18-labeled PET whole-body scan undergo a whole-body copper Cu 64 TP3805-labeled PET scan. No F-18-FDG Scan Positron Emission Tomography STAGE II: Patients with a positive biopsy, but no fludeoxyglucose F18 scan undergo a breast fludeoxyglucose F18-labeled PEM Positron Emission Mammography scan followed by a breast copper Cu 64 TP3805-labeled PEM scan. No F-18-FDG Scan Fludeoxyglucose F-18 STAGE II: Patients with a positive biopsy, but no fludeoxyglucose F18 scan undergo a breast fludeoxyglucose F18-labeled PEM Positron Emission Mammography scan followed by a breast copper Cu 64 TP3805-labeled PEM scan.
- Primary Outcome Measures
Name Time Method Number of F-18-FDG Positive Lesions That Are Detected by the Copper Cu 64 TP3805 Analog 4 hours after Cu 64 TP3805 administered Cu-64 results will be compared with those of F-18-FDG for: The unit of analysis will be the lesion (with potentially multiple lesions available per patient).
- Secondary Outcome Measures
Name Time Method Ability of Copper Cu 64 TP3805 to Detect Primary Breast Lesions as Determined by Histology (Sensitivity) 4 hours after Cu 64 TP3805 administered Optimal imaging time is the one (of the three) which will have least background activity in the surrounding tissue and image the maximum number of lesions with clarity. 95% confidence intervals will be used. To account for the multiplicity of lesions per patient, the GEE approach will be used, with the robust variance. Any adverse events will be summarized descriptively.