Open Label Clinical Study to Assess the Clinical Safety of a New Compression Procedure in Subjects With Peripheral Arterial Vascular Disease
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 15
- 试验地点
- 2
- 主要终点
- The primary objective of this study is to assess the safety of the new compression device in subjects with an ankle brachial pressure index (ABPI) between 0.5-0.8.
研究概览
简要总结
To assess the safety of a new compression device applied to patients with an ankle brachial pressure index (ABPI) 0,5 - 0,8 who are treated for two weeks in daily routine practice. Several perfusion assessments will investigate safety under reduced compression therapy.
详细描述
Venous leg ulcers represent a very common clinical problem with increasing prevalence in an aging population. It is believed that venous insufficiency is the underlying condition responsible for 54-81% of leg ulcers. About 8% of leg ulcers are related to arterial insufficiency and about 14% have a mixed aetiology. Compression therapy is considered the most effective treatment for these ulcers. The overall cost of chronic venous leg ulcer is high because long term ongoing care is required. Also the quality of life of these patients is jeopardized due to long lasting ulcer treatments and inconvenient compression therapies.
Several compression products are available on the market and there is a large body of literature describing the clinical benefit of different compression systems.
A new treatment approach with the new device is to have an effective working pressure combined with a low resting pressure. A high working pressure achieved by a rigid sleeve around a patient's leg is essential to support the muscle pump, necessary for sufficient blood reflux. However the resting pressure could be low without relevant reduction of compression efficacy but with an increase in safety for patients with a mild to moderate peripheral arterial occlusive disease (PAOD). A high resting pressure is believed to be a main reason for reduced arterial skin perfusion which can result in pressure related skin damage. Accordingly most compression systems are not indicated for patients with an ABPI lower than 0.8. About 25% of patients with chronic venous insufficiency suffer from PAOD and hence are very difficult to treat with compression. With the new device, these patients could be sufficiently treated, because a low resting pressure is believed to have low influence on skin perfusion.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Males or females, age 18 years or older.
- •Subjects suffering from peripheral arterial occlusive disease (PAOD) with an ABPI (ankle brachial pressure index) of the treated leg between 0.5 - 0.8 as measured within up to 4 weeks prior to enrollment. About 5 subjects of the study population should have an ABPI of 0.
- •Subjects who are co-operative, willing to give written informed consent prior to study entry and willing to comply with the study protocol.
- •Subjects who can walk (with or without a walking aid).
排除标准
- •Subjects with an ABPI < 0.5 or > 0.8 as measured within up to 4 weeks prior to enrollment.
- •Subjects whose general condition, in the opinion of the investigator, preclude for compression therapy.
- •Subjects with paralysis of the study leg
- •Subjects who started or significantly changed treatment with mood altering substances (e.g. antidepressant drugs) within two weeks prior to enrollment.
- •Subjects with significant instable coagulopathy; subjects treated with anticoagulant therapeutics can be included.
- •Subjects who are participating in any prospective clinical study that can potentially interfere with this study.
- •Subjects who are, in the opinion of the clinical investigator, unsuitable for enrollment in this study, for reasons not specified in the exclusion criteria.
- •Subjects with known allergies to other materials in the compression device.
结局指标
主要结局
The primary objective of this study is to assess the safety of the new compression device in subjects with an ankle brachial pressure index (ABPI) between 0.5-0.8.
时间窗: 2 weeks
次要结局
未报告次要终点