The Mechanical Properties of Burned Muscles
- Conditions
- Viscoelastic PropertiesBurnsStiffnessMuscle Loss
- Interventions
- Diagnostic Test: Myotonometric measurement
- Registration Number
- NCT04654572
- Lead Sponsor
- Hasan Kalyoncu University
- Brief Summary
The investigate of mechanical properties of muscles in burned patients.
- Detailed Description
The hypermetabolic response to severe burn is characterized by muscle protein catabolism. Current opinion states that the hypermetabolic state resolves soon after complete wound closure. Clinically, we have witnessed that burned patient appear to be hypermetabolic and catabolic long after full healing of their wounds. Our goal in this study was to determine muscle mechanical properties (tone, stiffness and elasticity) after burn.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 37
- burned patient
- major burn over %20 TBSA
- Amputation
- Dead
- Systemic disease and abuse
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description burned group Myotonometric measurement burned patients control group Myotonometric measurement sedentary people
- Primary Outcome Measures
Name Time Method Stiffness 6 week Myotonometric measurement was used to determine for muscle stiffness. Device has a probe that creates constant pre-excitations and generates short-term, low-force mechanical stimulations over skin. The stimulations induce damped natural oscillations in the tissue and the myoton device records these oscillations with an accelerometer. Muscle tone, elasticity, and stiffness are calculated separately by the device.
Tone 6 week Myotonometric measurement was used to determine for muscle tone. Device has a probe that creates constant pre-excitations and generates short-term, low-force mechanical stimulations over skin. The stimulations induce damped natural oscillations in the tissue and the myoton device records these oscillations with an accelerometer. Muscle tone, elasticity, and stiffness are calculated separately by the device.
Elasticity 6 week Myotonometric measurement was used to determine for muscle elasticity. Device has a probe that creates constant pre-excitations and generates short-term, low-force mechanical stimulations over skin. The stimulations induce damped natural oscillations in the tissue and the myoton device records these oscillations with an accelerometer. Muscle tone, elasticity, and stiffness are calculated separately by the device.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Hasan kalyoncu üniversity
🇹🇷Gaziantep, Turkey