The Use Of Specially Designed Probe Versus Cone- Beam Computerized Tomography In The Measurement Of Gingival Thickness: Diagnostic Accuracy Study
试验速览
- 阶段
- 不适用
- 入组人数
- 24
- 主要终点
- Special Designed Probe
研究概览
简要总结
Accurate measurement of gingival thickness is crucial for decision making in the field of Periodontology and implant dentistry. Currently implemented techniques for the detection of gingival biotype are of limited reliability. They possess different drawbacks leading to the necessity for the development of a new method to overcome disadvantages of the available techniques.
the rational of this study is to determine the accuracy of a specially designed probe in comparison to cone- beam computerized tomography which is accurate enough as found by Fu et al 2010.
详细描述
The success of the esthetic outcome for the anterior teeth restorations and periodontal surgeries depends on several factors such as the gingival biotype, teeth alignment and architecture of the gingiva.
The first who introduced the term biotype are Seibert and Lindhe 1989, they categorized the gingiva to ''thick-flat'' and ''thin-scalloped'' biotypes . Thick biotype is associated with broad tissue and flat gingiva which is also supported by thick bony plate. Thin biotype is associated with thin band of keratinized tissue and scalloped gingiva which is supported by thin bony plate.
A gingival thickness of more or equal to 2 mm is defined as thick biotype and a gingival thickness of less than 1.5 mm as thin biotype. Different gingival biotypes response in different ways to inflammation, restorative and periodontal surgery .
The gingival thickness may predict the outcome of periodontal and restorative treatments. For implant surgery, implant in thin biotype will lead to future peri-implant mucosal recession . The gingival thickness affects the treatment outcome possibly because of the difference in the amount of blood supply of the underlying bone and susceptibility to resorption .
Multiple techniques were proposed to measure the tissue thickness , such as direct measurement ultrasonic devices probe transparency method and cone-beam computed tomography scan
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Cross Sectional
入排标准
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Special Designed Probe
时间窗: finish the trial in 1 years from the clinical trial registration ( May 2019)
Assessment of the diagnostic accuracy of Specially designed probe in measuring the gingival thickness in millimeter unit
次要结局
未报告次要终点
研究者
Deyaa Darwish
pricipale investigator
Cairo University