跳至主要内容
临床试验/JPRN-UMIN000038276
JPRN-UMIN000038276已完成未知

Evaluation of rapid diagnostic test in the patients with influenza - Evaluation of rapid diagnostic test in the patients with influenza

Department of Laboratory Medicine, Nagasaki University Hospital0 个研究点目标入组 244 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
未知
状态
已完成
发起方
入组人数
244

研究概览

简要总结

In nasopharyngeal swabs, based on the combined RT-PCR and sequencing results, the sensitivity, specificity, PPV, and NPV of TRC for influenza detection were 0.990, 1.000, 1.000, and 0.993, respectively. In the gargle samples, the sensitivity, specificity, PPV, and NPV of the TRC for detecting influenza were 0.970, 0.982, 0.980, and 0.974, respectively.

研究设计

研究类型
Observational

入排标准

年龄范围
ot applicable 至 ot applicable(—)
性别
All

入选标准

  • 未提供

排除标准

  • Patient who was administered anti-influenza agents within one month.

研究者

发起方
Department of Laboratory Medicine, Nagasaki University Hospital

相似试验