临床试验/NCT04798742
NCT04798742已完成不适用

Gluteus Maximus Transfer Following THA Does Not Improve Abductor Strength - a Case-control Gait Analysis Study of 15 Patients With Gluteus Medius Disruption

Göteborg University2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2012年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
15
试验地点
2
主要终点
Abductor strength measurement with use of an optical tracking system after Gluteus maximus transfer- a case-control gait analysis study of 15 patients pre- and postoperative with gluteus medius disruption

研究概览

简要总结

Gluteus maximus transfer following THA does not improve abductor strength - a case-control gait analysis study of 15 patients with gluteus medius disruption

The investigators have compared 15 gluteus maximus transferred patients with the use of a gait analysis system based on reflective markers and force plates to objectively evaluate the gait performance pre- and postoperatively.

详细描述

The gluteus maximus flap transfer (GMT) is a surgical technique to improve gait kinematics and kinetics as well as reduce pain and ameliorate functional outcome in patients with hip abductor deficiency of the gluteus medius following total hip arthroplasty (THA). The investigators used a gait analysis system based on reflective markers and force plates to objectively evaluate gait performance pre- and postoperatively.

Methods Gait analysis was performed in 15 patients who underwent GMT and were examined with an optical tracking system before and at a minimum of 13 months after the operation. Mean age was 69 years (SD=11), all were females. Median follow-up time was 24 (13-60) months. The primary outcome was hip abduction moment (Nm/kg) during gait. The control group consisted of 66 subjects without any gait pathology.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

性别
Female
接受健康志愿者

入选标准

  • Patients with hip abductor deficiency of the gluteus medius following total hip arthroplasty (THA)

排除标准

  • THA prior to the muscle transfer

结局指标

主要结局

Abductor strength measurement with use of an optical tracking system after Gluteus maximus transfer- a case-control gait analysis study of 15 patients pre- and postoperative with gluteus medius disruption

时间窗: Postop 2 year

Gait analysis examination/measure will be performed 2 year postoperative with an optical tracking system in a gait laboratory using reflective markers and integrated force plates in order to record kinetics (Nm/kg) of abductor muscles moment in the frontal plane.

Abductor strength measurement with use of an optical tracking system after Gluteus maximus transfer - a case-control gait analysis study of 15 patients pre- and postoperative with gluteus medius disruption

时间窗: Preop

Gait analysis examination/measure will be performed preoperative with an optical tracking system in a gait laboratory using reflective markers and integrated force plates in order to record kinetics (Nm/kg) of abductor muscles moment in the frontal plane.

次要结局

未报告次要终点