主要终点
Holger's Scale

研究概览

简要总结

To assess implant stability, implant loss, adverse skin reactions, and Quality of Life Benefit following implantation of the Ponto 4.5mm Wide Diameter implant. Secondary: to determine the feasibility of fitting the sound processor 3 weeks after surgical implantation, and to investigate if the type of skin reactions following implantation could be related to the demographic data of subjects and the type of surgical technique used

详细描述

Bone-anchored hearing systems have been an amplification choice for conductive, mixed, and profound, unilateral, sensorineural hearing loss for over three decades. So far, about 75,000 patients worldwide have received this surgical intervention (bone-anchored hearing system), since its first successful implantation in 1977. In 2009, Oticon Medical, LLC launched its bone-anchored hearing system called Ponto. In just over two years, the Ponto has been successfully implanted in over 3,000 patients by leading otolaryngologists and neurotologists in 18 countries worldwide.

The Ponto implant has previously been available with a 3.75mm diameter and comes in two lengths: 3mm and 4mm. Anew Ponto implant that is 4.5mm wide in diameter is now available in both 3mm and 4mm lengths. This Wide Diameter implant is designed to maximize bone-to-implant contact area and enhance implant stability which can potentially allow loading of the sound processor as early as 3 weeks after surgery. The abutment screw incorporates external threads at the screw head to make it possible to connect a SmartPeg (Osstell, Goteborg, Sweden) for stability measurements. All Ponto implants have the same universal implant-abutment interface. Therefore, they are fully compatible with existing instruments and abutments. Two new countersinks have been developed for the new Ponto Wide Diameter implant. The drill size of the countersink is 3.80mm. It is marked with a "W" to separate them from existing drills. All products are CE-marked and cleared for the US market by the FDA.

Objectives The present study will attempt to show that the Ponto 4.5mm Wide Diameter implant has similar or better outcomes in terms of Quality of Life (QoL) benefit; implant extrusion and revision surgery when compared to the 3.75mm diameter implant. Secondary objectives to be studied will include adverse skin reactions, the feasibility of fitting the sound processor three weeks after surgical implantation, and investigation to see if the type of skin reactions observed following implantation could be related to the demographic data of subjects or the type of surgical technique used.

Study Design This study is a prospective, multicenter study of subjects' demographic and implant data. Subjects will be enrolled at two US sites.

Subject Population Twenty adult subjects 18 years or older will be included in the study from each participating partner site.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • conductive, mixed or single sided deafness
  • 18 years of age or older

排除标准

  • younger than 18 years of age

研究组 & 干预措施

Wide diameter bone anchored implant

Other

Intervention: Implantation of a wide diameter bone anchored auditory implant either 3 or 4 mm in length, into the skull on the side of the ear where intervention is intended in order to restore hearing. In the case of a conductive or mixed hearing loss, that side is chosen. In patients with unilateral, profound sensori-neural hearing loss the implant is implanted on that side but the sound is transmitted to the side with the normal hearing ear via bone conduction stimulation.

干预措施: Wide diameter bone anchored implant (Device)

结局指标

主要结局

Holger's Scale

时间窗: 1 week, 3 weeks, 6 weeks, 3 months, 6 months and 12 months

Holger's Scale is a 5 point that ranges from 0 - 4 scale that assesses skin reactions at the implant site where 0 means no reaction and 4 means excessive granulation, skin overgrowth, or scar formation requiring revision surgery

Implant Stability as Measured by the Osstell Implant Stability Quotient in the Vertical and Horizontal Plane

时间窗: At surgery, 1 week, 3 weeks, 6 weeks, 12 weeks, 6 months and 12 months

Presently, the recommendations to load the sound processor on a bone anchored implant is 3 months (for adults). Using outcome measures, i.e., OSSTELL ISQ ranges from 0 -100 where 0 is least stable and 100 being the most stable.

次要结局