跳至主要内容
临床试验/NCT03088683
NCT03088683Unknown不适用

Comparison of Liver Trauma in Two Retractors Used in Sleeve Gastrectomy: A Prospective Multicenter Clinical Trial

Umraniye Education and Research Hospital1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2017年1月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
发起方
入组人数
60
试验地点
1
主要终点
Changes in physiological parameters of liver due to trauma of retractors

研究概览

简要总结

In Laparoscopic Sleeve Gastrectomy, retraction of the left lobe of the liver is important for an effective visualisation. There are many retractors available for this retraction. A study is designed to compare two different liver retractors for liver trauma; Nathanson liver retractor that is used more commonly and Reveel liver retractor that has more recent history of use.

详细描述

A randomised controlled prospective study is designed with 80 patients over 3-month period (January 2017 to March 2017). Laparoscopic sleeve gastrectomy is planned for all patients. Two groups are designed depending on retractor. Liver retraction will be provided with Nathanson retractor in first group (Nathanson group, 40 patients), and with Reveel retractor in second group (Reveel group, 40 patients). Preoperative serum levels of transaminases, total bilirubin and C-reactive protein will be measured in all patients. The same biochemical markers will be measured on days 1 and 2 postoperatively. The patients with body mass index (BMI) ≥35kg/m2 are enrolled to study. The parameters of demographic characteristics (age, gender, BMI, weight, and body fat percentage), and clinical outcomes (postoperative complications, mortality, readmissions) are planned to record.

Operative Technique

All patients will be operated by same surgeons. and anesthetist. Peroperatively intravenous paracetamol 10 mg, tramadol 50 mg and fentanyl 150 mcg will be used for analgesia. Laparoscopic sleeve gastrectomy will be performed with 5 trocars, in reverse trendelenburg position by creating pneumoperitoneum with 14 mmHg carbon dioxide insufflation. Trocar replacements are one 10-mm trocar in the midline above umbilicus for the endoscope, one 12-mm trocar to right midclavicular line linage to the 10-mm trocar. One 5-mm trocar to the left midclavicular line linage to the 10-mm trocar, one 5-mm trocar to the front axillary line below the left costal margin. Both liver retractors will be placed from 2 cm below the xiphoid process for liver retractor. In nathanson group; after placing the blade of Nathanson retractor below the left lobe of the liver, it will be fixed to the operating table by the other instruments of retractor. In reveel group; the retractor will be placed below the left lobe of the liver and then it will be fixed to the skin with a towel clamp. 38 F orogastric tube will be used. No use of nasogastric tubes and urinary catheters routinely is planned. Drain replacement is planned for all patients.

Preoperative and postoperative values of the markers will be analysed and compared between two groups.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •patients with BMI>35

排除标准

  • •patients with known liver disease

研究组 & 干预措施

Nathanson Retractor

Active Comparator

Nathanson retractor will be used

干预措施: Nathanson Retractor (Device)

Reveel Retractor

Active Comparator

Reveel retractor will be used

干预措施: Reveel Retractor (Device)

结局指标

主要结局

Changes in physiological parameters of liver due to trauma of retractors

时间窗: within the first 2 days of the surgery

Traumatic effects of liver retractors in sleeve gastrectomy. Number of participants with abnormal laboratory values.

次要结局

未报告次要终点

研究者

发起方
Umraniye Education and Research Hospital
申办方类型
Other Gov
责任方
Principal Investigator
主要研究者

Abdullah Sisik

General Surgery Specialist

Umraniye Education and Research Hospital

研究点 (1)

Loading locations...