Cancer Sensing: Evaluation of Odour Sampling Techniques

Completed
Conditions
Skin Cancer
Interventions
Other: Solid Phase Microextraction (SPME)
Other: Absorptive patch
Registration Number
NCT04206995
Lead Sponsor
Bournemouth University
Brief Summary

To evaluate the suitability of two odour capturing techniques for early detection of skin cancer.

Detailed Description

The study will investigate the suitability of two odour capturing techniques for early detection of skin cancer. The techniques to capture VOCs are: a) solid phase microextraction (SPME) and b) collection of VOCs via an adsorptive patch, worn on the skin. The objective is to evaluate the suitability of two techniques for collecting VOCs.

Odour samples from cancerous and healthy skin will be captured using the two non-invasive techniques. The techniques will initially be tested in a laboratory environment. They will then be applied in parallel to patients and healthy people. VOC compounds of odour samples will be analysed for their profiles in respect of cancerous and healthy skins. The VOCs profiles will be recorded in a VOC bank for future analysis.

Following the initial tests, patients (n=20) with skin cancer will be recruited from Poole and Dorset County Hospitals. Arrangement will be made to obtain odour samples by positioning patches on the cancerous skin sites (for approximately 30 minutes) of patients and recover them. To obtain samples from healthy people (n=10), staff and students within the university are invited to participate in this research by providing odour samples from their skins using the same type of patches.

In parallel, VOCs from skin cancer patients will also be collected from patients with the SPME fibres described earlier. The SPME device is roughly equivalent in size and shape to a ballpoint pen, from the tip of which an adsorbent fibre can be extended. The SPME device is held statically with a flexible clamp (a weighted clamp which rests on a bench / desk near the patient), and is positioned so that the tip of the fibre rests close to, but not touching, the affected skin area. The fibre needs to be held in place to sample the air above the affected skin for a pre-determined period of time, likely to be 15 - 30 minutes. Specifics such as the sampling time and related factors will be evaluated during the initial laboratory testing. Following the defined time period of sampling, the fibre is retracted into the body of the SPME device (to protect it), and the device is returned to the laboratory for analysis. The high temperatures involved in GCMS analysis cause VOCs captured by the SPME device to be released (desorbed) and they are subsequently swept through the GCMS system for analysis.

The VOC samples from both the techniques will be transported to Bournemouth university for analysis.

The outcome will be the identification of the most suitable VOC collection technique (SPME vs patch) by comparing the VOC profiles of cancerous and healthy skin.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
20
Inclusion Criteria
  • Patients diagnosed with skin cancer, able to speak and understand written English,
  • 18 years or older and
  • Capable of giving informed consent.
Exclusion Criteria
  • Patients too weak to speak or give written informed consent;
  • Non-English speaking without an interpreter;
  • Patients lacking mental capacity to consent, or
  • Below the age of 18.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Evaluation of odour capturing techniquesSolid Phase Microextraction (SPME)To evaluate two odour capturing techniques to compare VOC profiles of cancerous and healthy skin cancer.
Evaluation of odour capturing techniquesAbsorptive patchTo evaluate two odour capturing techniques to compare VOC profiles of cancerous and healthy skin cancer.
Primary Outcome Measures
NameTimeMethod
Evaluate the suitability of the adsorptive patch for collecting VOCs for analysis for early identification of skin cancer.30 minutes

An adsorptive patch, covering skin cancer and healthy skin sites will be applied for a period of maximum 30 minutes to capture VOCs. No drug will be used. This is to investigate the capability of the technique in capturing VOCs.VOCs for analysis for early identification of skin cancer.

Evaluate the suitability of the Solid Phase Microextraction (SPME) for analysis for early identification of skin cancer.30 minutes

A SPME fibre is held directly above skin cancer, or healthy skin for a period of less than 30 minutes to capture VOCs. No drug will be used. This is to investigate the capability of the technique in capturing VOCs.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (2)

University Hospitals Dorset NHS Foundation Trust

🇬🇧

Poole, Dorset, United Kingdom

Dorset County Hospital NHS Foundation Trust

🇬🇧

Dorchester, Dorset, United Kingdom