MedPath

A Prospective, Clinical Investigation of the Vanguard 360 Revision Knee

Recruiting
Conditions
Rheumatoid Arthritis
Traumatic Arthritis
Deformity of Limb
Post Traumatic Deformity
Complications; Arthroplasty
Osteoarthritis
Interventions
Device: Vanguard SSK 360 with PS Bearing
Device: Vanguard 360 TiNbN Femur with PSC bearing
Device: Vanguard 360 TiNbN Femur with PS bearing
Device: Vanguard SSK 360 with PSC bearing
Device: Vanguard DA 360
Registration Number
NCT01542580
Lead Sponsor
Zimmer Biomet
Brief Summary

The purpose of this study is to evaluate performance of the Vanguard 360 revision knee system utilizing offset on either the tibial component, femoral component, or both in terms of the restoration of mechanical alignment, clinical outcomes and survivorship.

Detailed Description

This investigation is being conducted on a new complete revision knee system, Vanguard 360, which incorporates:

* Fixed Bearing Knee - Vanguard SSK360 with PS Bearing and PSC Bearing

* Fixed Bearing Knee - Vanguard SSK360 TiNbN Femur with PS Bearing and PSC Bearing

* Mobile Bearing Knee - Vanguard DA360 (only being collected in Europe)

The purpose of this study is to evaluate performance of the Vanguard 360 revision knee system utilizing offset on either the tibial component, femoral component, or both in terms of the restoration of mechanical alignment, clinical outcomes and survivorship.

The efficacy and performance of the devices will be assessed by improvement of pain, function, range of motion and patient satisfaction measured pre-operatively and post-operatively. Secondary performance and safety will be determined by radiographic investigation, incidence of complications and revision rates.

Surgical techniques and patient care are to be standard for the surgeon participating in the protocol. There will be no experimental or investigational devices used. There will be no experimental or investigational surgical techniques used. The devices and products will be used in accordance with their instructions for use and/or approved labeling.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
255
Inclusion Criteria
  • Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis where one or more compartments are involved.
  • Correction of varus, valgus or post-traumatic deformity
  • Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure
  • Ability and willingness of the patient to attend follow-up visit.
  • Willing to give written informed consent
  • Patients are at least 18 years of age, no upper age limit, must have reached full skeletal maturity.
Exclusion Criteria
  • infection
  • sepsis
  • osteomyelitis

Relative Contraindications:

  • An uncooperative patient or a patient with neurologic disorders who is incapable of following directions
  • Osteoporosis
  • Metabolic disorders which may impair brain function
  • Osteomalacia
  • Distant foci of infections which may spread to the implant site
  • Rapid joint destruction, marked bone loss, or bone resorption apparent on roentgenogram
  • Vascular insufficiency, muscular atrophy, neuromuscular disease
  • Incomplete or deficient soft tissue surrounding the knee

Additional research-related exclusion criteria: patients who have a history of or current infection in the affected knee.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Vanguard SSK 360 with PS BearingVanguard SSK 360 with PS BearingPatients enrolled using a Vanguard SSK 360 Posterior-Stabilized (non-constrained) tibial bearing.
Vanguard 360 TiNbN Femur with PSC BearingVanguard 360 TiNbN Femur with PSC bearingThe Vanguard 360 TiNbN is the same system and functions in the same manner as the non-coated device.
Vanguard 360 TiNbN Femur with PS BearingVanguard 360 TiNbN Femur with PS bearingThe Vanguard 360 TiNbN is the same system and functions in the same manner as the non-coated device.
Vanguard SSK 360 with PSC BearingVanguard SSK 360 with PSC bearingPatients enrolled using a Vanguard SSK 360 Posterior-Stabilized Constrained tibial bearing.
Vanguard DA 360Vanguard DA 360Patients enrolled using a Vanguard DA 360 component.
Primary Outcome Measures
NameTimeMethod
AMERICAN KNEE SOCIETY KNEE SCORE24 months postoperative

Improvement of American Knee Society Knee Score between pre-operative and 2 years post-operative follow up

Secondary Outcome Measures
NameTimeMethod
Survivorship10 years postoperative

Survivorship at 10 years post-operative follow up

Trial Locations

Locations (12)

Illinois Bone and Joint

🇺🇸

Morton Grove, Illinois, United States

Orthopedic Institute of Henderson

🇺🇸

Henderson, Nevada, United States

University of Utah Orthopedic Center

🇺🇸

Salt Lake City, Utah, United States

OrthoVirginia West End Orthopedic Clinic

🇺🇸

Richmond, Virginia, United States

University Hopital Pellenberg

🇧🇪

Pellenberg, Belgium

Aarhus university hospital

🇩🇰

Aarhus, Denmark

Ch Lyon Sud

🇫🇷

Lyon, France

Klinik fur Endoprothetik und gelenkchirurgie

🇩🇪

Bad Wildbad, Germany

IRCCS Istituto Ortopedico Galeazzi

🇮🇹

Milano, Italy

Azienda Ospedaliero Universitaria Pisana

🇮🇹

Pisa, Italy

University Hospital Mutua de Terrasa

🇪🇸

Terrassa, Spain

Royal Orthopaedic Hospital

🇬🇧

Birmingham, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath