Mechanism of Chemoreflex and Baroreflex Alterations Causing Postural Tachycardia Syndrome in POTS Patients With Orthostatic Hyperpnea and Hypocapnia
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 30
- 试验地点
- 2
- 主要终点
- Orthostatic Changes in Cerebral Blood Flow
研究概览
简要总结
Postural tachycardia syndrome (POTS) is the most common chronic cause of postural lightheadedness, and upright confusion afflicting many Americans, mostly young women. Many POTS patients hyperventilate by increasing their depth of breathing that produces tachycardia, alters blood flow and blood pooling in the body and importantly reduces brain blood flow causing "brain fog". In this proposal the investigators will demonstrate in young women that abnormal repeated brief impairment of blood pressure and brain flow just after standing sensitizes the body's oxygen sensor in POTS to respond as if it were in a low oxygen environment causing hyperventilation and its consequences. In this project the investigators will use various drugs that will help to understand the mechanisms that cause POTS in this unique subset of POTS patients who hyperventilate.
详细描述
The Investigators will compare results from female POTS patients, free of known pulmonary or sleep disorders aged 15 to 39 years with, and without orthostatic hyperpneic hypocapnia, to healthy female volunteers with the following two (2) specific aims:
- To test poikilocapnic (allowing carbon dioxide (CO2) to vary) orthostatic cardiorespiratory responses to determine whether prolonged initial orthostatic hypotension (IOH) precedes upright hypocapnia in hyperpneic POTS but not in controls or non-hyperpneic POTS. Subjects are instrumented for cerebral blood flow, respiratory and hemodynamic measurements, investigating splanchnic blood flow by indocyanine green infusion, and measuring changes of CBV, regional blood volumes, and cardiac output (CO) by impedance plethysmography during a 10 min stand to quantify IOH, and a 10 min tilt test to 70⁰ to quantitate cardiorespiratory changes. These changes during tilt stratify hyperpneic and non-hyperpneic POTS.
- To test if chemoreflex sensitization of ventilation and sympathetic activity (by microneurography) are abnormal when supine and tilted upright at 45o and how that interacts with Oxford measured cardiovagal and sympathetic baroreflexes under controlled gas conditions which are: isocapnic hypoxia and isocapnic hyperoxia to measure carotid body reflex; hyperoxic isocapnia and hyperoxic hypercapnia to measure central chemoreflexes. Hyperoxia silences peripheral chemoreceptors and will normalize baroreflex and tilt responses.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 15 Years 至 39 Years(Child, Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •The investigators will recruit female POTS cases (N=80) and healthy female control subjects (N=40) aged 15-39 years, matched for BMI. POTS is a disease in which 80-90% are females. Therefore, the investigators will only recruit female POTS patients and controls.
排除标准
- •Any subjects with systemic disease or who cannot stop taking prescribed medications for at least 2 weeks prior to study.
结局指标
主要结局
Orthostatic Changes in Cerebral Blood Flow
时间窗: Baseline in all subjects
Cerebral Blood Flow (cm/s) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Orthostatic Blood Pressure Changes
时间窗: Baseline in all subjects
Blood pressure (mmHg) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Orthostatic Changes in Segmental Blood Flow
时间窗: Baseline in all subjects
Segmental Blood Flows (ml•min-1•100 ml tissue-1) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Orthostatic Changes in Systemic Vascular Resistance
时间窗: Baseline in all subjects
Systemic vascular resistance (mmHg⋅min⋅mL-1) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Orthostasis Induced Depth of Breathing
时间窗: Baseline in all subjects
Changes in the depth of breathing (L of inhaled air per minute) will be determined in all subjects before and after being tilted upright on a tilt table.
Effects of chemoreflex activation on baroreflexfunction and the effects of baroreflex on chemoreflex sensitivity
时间窗: Baseline in all subjects
Supine chemoreflex activation using controlled gas conditions which are: isocapnic hypoxia and isocapnic hyperoxia to measure carotid body reflex; hyperoxic isocapnia and hyperoxic hypercapnia to measure central chemoreflexes. Hyperoxia silences peripheral chemoreceptors and will normalize baroreflex and tilt responses) should alter baroreflex function measured as the change in RR Interval (reciprocal of heart rate) in milliseconds per millimeter of mercury change in systolic blood pressure). This will be performed both supine and during 45 degree tilting which will activate the baroreflexes and reduce chemoreflex responses.
Orthostatic Blood Volume Changes
时间窗: Baseline in all subjects
Central Blood Volume in liters (L) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Orthostasis Induced Rate of Breathing
时间窗: Baseline in all subjects
Changes in the rate of breathing (breaths per minute) will be determined in all subjects before and after being tilted upright on a tilt table.
Orthostatic tachycardia
时间窗: Baseline in all subjects
Heart rate (beats per minute) delimit the orthostatic response. Two separate orthostatic tests are used: a standing test and a 70 degree upright tilt test. The standing test will delineate the carotid blood flow signal that sensitizes the carotid body chemoreflex. The tilt test will delineate the effects of sustained tachyardia (and hyperpnea) on systemic hemodynamics and breathing.
Measurement of chemoreflex sensitivity carotid body chemoreflex and central chemoreflex
时间窗: Baseline in all subjects
Paired hypoxia and isocapnic hyperoxia determine the carotid body chemoreflex sensitivity; measurements of ventilation and sympathetic activation using Muscle Sympathetic Nerve Activity (MSNA - mean burst frequency and normalized mean burst area and expressed as arbitrary units (AU) per minute) define the responses. Similarly, measurement of during isocapnic hyperoxia and hypercapnic hyperoxia determine central chemoreflex stressors - measure sympathetic activity as responses.
次要结局
- Systemic changes in abdominal blood volumes during orthostatic testing.(Baseline in all subjects)
- Systemic changes in leg blood volumes during orthostatic testing.(Baseline in all subjects)
研究者
Marvin Medow
Professor of Pediatrics