NCT02206438CompletedNot Applicable

The Clinical Efficacy of Supraglottic Airway Device, Self-pressurized Air-Q Intubating Laryngeal Airway (ILA -SP) in Adult Patients: Comparison With Classic-laryngeal Airway (c-LMA)

Yonsei University1 site in 1 country84 target enrollmentStarted: July 1, 2014Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
84
Locations
1
Primary Endpoint
airway leak pressure measured after device insertion

Study Overview

Brief Summary

Supraglottic airway devices (SADs) are well established in anesthetic practice. Among these devices ,classic laryngeal airway has been typically widely used. The self-pressurised air-Q (air-Q) is newly developed supraglottic airway devices. It is a new single-use device that may optimise the airway sealing while reducing the potential for postoperative complications such as sore throat. The overall structure of the air-Q SP is identical to the original air-Q, except with regard to the inflatable cuff. The aim of this randomized trial was to compare the clinical performance of the classic LMA and the air-Q SP.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Other
Masking
Double (Participant, Outcomes Assessor)

Eligibility Criteria

Ages
20 Years to 75 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Adult patients (20-75 of age) scheduled for elective surgery of short duration (less than 2 hr) undergoing general anesthesia using supraglottic airway

Exclusion Criteria

  • •Patients with a potentially difficult airway, risk of aspiration such as gastroesophageal reflux disease, or active upper respiratory tract infection

Arms & Interventions

1)C-LMA group

Experimental

Intervention: Insertion of C-LMA (Device)

2)Air-Q group

Active Comparator

Intervention: Insertion of air-Q according (Device)

Outcomes

Primary Outcomes

airway leak pressure measured after device insertion

Time Frame: within 5min to 10 min insertion of each device

Airway leak pressure was determined by adjusting the expiratory valve of the breathing circle to 40 cmH2O (fixed fresh gas flow 3 L/min) and recording the pressure when equilibrium was reached.

Secondary Outcomes

  • Insertion time(During and 1 min after insertion of each device)