MedPath

The ION Facet Screw System Ambispective Evaluation

Active, not recruiting
Conditions
Intra-facet ION 3D Facet Screw System
Registration Number
NCT06720948
Lead Sponsor
SurGenTec LLC
Brief Summary

The purpose of this observational, multi-center, ambispective, serial case study is to collect real-world patient outcomes that characterize the long-term safety and effectiveness of the SurGenTec ION 3D® Facet Screw System in a cervical spine and a lumbar spine application.

Detailed Description

The statistical analysis of the data obtained from this study will be performed using a validated statistical software program such as SPSS®. All tests will be performed at the 0.05 significance level, unless otherwise specified. Analysis will be based upon the treated population defined as all subjects that underwent standard of care surgical intervention with the SurGenTec ION 3D Facet Screw System that agreed to participate in this data collection initiative.

Data collected in this study will be documented using summary tables and subject data listings. Continuous variables will be summarized using descriptive statistics, specifically the mean, median, standard deviation, minimum, and maximum, and a 95% confidence interval for the mean based on the t-distribution. Categorical variables will be summarized using frequencies, percentages, and 95% confidence intervals for the true proportions. Resultant of the observational study design, this evaluation is not powered to test a hypothesis. It is designed to yield supplemental long-term information in this real-world population.

The analysis will be stratified by lumbar and cervical patients. Additionally, each cohort will evaluate the following analysis populations:

Enrolled Population: This dataset will include all subjects who were screened and enrolled into the study.

Evaluable Population: This dataset will exclude subjects with ION 3D Facet Screw device improperly placed

To minimize the introduction of bias into this observational low risk evaluation, the following measures will be observed:

* Complete and accurate prespecified data shall be obtained,

* All cervical and all lumbar patients at a study site that were previously implanted with the ION 3D Facet Screw System will be reviewed for possible study inclusion (all-comers study design),

* All participants will be enrolled under the same study entrance criteria,

* All participants shall follow the same prospectively designed study protocol,

* Serious Adverse Event adjudication will be performed by independent blinded reviewer, and

* Radiographic measurements and CT assessments will be performed by blinded independent core lab.

In consideration of the retrospective nature of this investigation coupled with a possible 1-time prospective evaluation, data monitoring will not be performed. However, data edits and database checks will be built into the EDC system to minimize the potential for data entry errors. Further, TSN, as the entity responsible for overall study conduct/management, will review all data entered and ensure appropriate source documentation is available to support data extraction/collection.

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Previously implanted intra-facet with one ION® Facet Screw placed per joint bilaterally at one or more contiguous levels of the cervical spine (C3-C7), or one or more contiguous levels of the lumbar spine (L3-S1),
  • Must have supplemental fixation at the target level(s),
  • Skeletally mature (minimum age of 21 years but not greater than 80 years),
  • Be willing and able to comply with the study protocol requirements, and
  • Be willing to sign the study-specific Informed Consent Document.
Exclusion Criteria
  • Implanted with the ION Facet Screw System at a spinal level that includes the thoracic spine (T1-T12),
  • Unilateral fixation with the ION Fact Screw System,
  • Current tobacco use
  • Body Mass Index of >40,
  • Current active or suspected malignancy, or a cancer diagnosis that was ongoing during the patient's treatment and healing period,
  • Significant metabolic bone disease (diagnosis of osteoporosis or osteomalacia),
  • Currently taking medications that are known to potentially interfere with bone healing (e.g. chronic oral/systemic steroids),
  • Pregnant or nursing female, or
  • Incarcerated at the time of the required 12-month evaluation.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Rate of Qualitative Fusion12 Months Post-Op

Bridging bone present external to the ION 3D facet screw device as observed on CT scan.

Rate of Quantitative Fusion12 Months Post-Op

Defined as \<5 degrees of angulation and/or \<3mm translation as measured on dynamic flexion and extension radiographs

Rate of Stability of operative level(s)12 Months Post-Op

Substantial motion defined as \>5 degrees angulation and/or \>3mm translation as measured on dynamic flexion and extension radiographs.

Incidence of Serious Adverse Events12 Months Post-Op

Freedom from ION 3D facet screw device-related serious adverse events as adjudicate by an independent reviewer.

Incidence of Secondary Surgical Events12 Months Post-Op

Secondary surgical events at the operative level(s) from intraoperative through ≥12-month evaluation timepoint.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (2)

Orthopaedics Northeast

🇺🇸

Fort Wayne, Indiana, United States

Neuroscience Specialists

🇺🇸

Oklahoma City, Oklahoma, United States

© Copyright 2025. All Rights Reserved by MedPath