NL-OMON34209已完成4 期
Accuracy of achieved correction of open versus closed wedge high tibial osteotomies, with locking plate fixation - Comparison of two osteotomy techniques of the tibia
适应症
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 入组人数
- 124
研究概览
简要总结
暂无简介。
研究设计
- 研究类型
- Interventional
入排标准
- 年龄范围
- 18 至 99(—)
入选标准
- •knee pain located over the medial tibiofemoral compartment of the knee, knee pain for more than 3 months, with a severity of the knee pain of more than 20 mm on a VAS score (range 0 to 100 mm), radiographic signs of knee OA, defined by a Kellgren & Lawrence score of grade 1-3, and presence of varus malalignment as measured on a whole leg radiograph.
排除标准
- •OA of the lateral compartment, grade-3 collateral ligament laxity, range of motion of < 100°, a flexion contracture of > 10°, history of fracture or previous open operation of the lower limb, ACL rupture, rheumatoid arthritis, patients with a contralateral HTO will be excluded if the first knee has been included in this trial; thus, if both knees are symptomatic, only the first knee will be included, patients from whom it is not sure that they will be able to attend the follow-up measurements, insufficient command of the Dutch language, spoken and/or written.
研究者
相似试验
招募中
不适用
Accuracy of achieved correction of open versus closed wedge high tibial osteotomies, with locking plate fixation.Medial compartment osteoarthritis of the kneeNL-OMON25898Erasmus Medical Center, Department of Orthopaedics124
尚未招募
不适用
Vergelijking van twee standscorrectie operaties van het onderbeen bij knieartrose.Patients, age 18–60, with isolated medial compartment osteoarthritis (OA), concomitant with a varus mechanical axis of the knee, good range of motion and limited ligamentous knee laxity.NL-OMON24339Erasmus University Medical CenterRotterdamThe Netherlands124
进行中(未招募)
不适用
Comparison of the accuracy of the virtual result obtained by the Treatment with the Tooth Aligner of the company Invisalign® with the actual result achievedOrthodontic Appliances RemovableC07.793.494RBR-7df547hniversidade Federal de Minas Gerais
已完成
不适用
Comparison of calibration accuracy between point-of-care devices and glucometers when using personal CGMtype 2 diabetesJPRN-UMIN000042667Inuyama Chuo General Hospital16
招募中
Unknown
Evaluation of the effect of improved accuracy of femoral component rotation angle on clinical outcomes in total knee arthroplasty using ROSA Knee, a robotic surgical assistant: A prospective, randomized controlled study with or without the use of the Femoral Rotation ToolOsteoarthritis, Rheumatoid arthritisJPRN-UMIN000049164Fujita health university160
