Skip to main content
Clinical Trials/NCT04942756
NCT04942756UnknownNot Applicable

GLYPALCARE STUDY - Multicenter, Randomized Study for Evaluating Continuous Glucose Monitoring (CGM) by Using FreeStyle Libre 2 (FSL2) for Preventing Hyperglycemia/Hypoglycemia Crisis in Advanced Oncological Patients With Known/Newly Diagnosed Type I/Type II Diabetes Mellitus (DM) in Palliative Care/ Supportive Care (PC/SC) Setting.

Antea Foundation6 sites in 3 countries118 target enrollmentStarted: June 30, 2021Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Sponsor
Enrollment
118
Locations
6
Primary Endpoint
Evaluate CGM by using FSL2 in preventing severe hyperglycemia peaks

Study Overview

Brief Summary

Cancer patients with known or newly diagnosed (i.e. iatrogenic) Diabetes Mellitus (DM) in Palliative/Supportive Care will be enrolled. Patients will be randomly assigned to one of two groups. Patients included in the first group will monitor glucose levels through Continuous Glucose Monitoring (CGM), using the FreeStyle Libre 2 (FSL2). The second group is represented by the usual standard way for blood glucose (BG) monitoring (lancing device for finger samples). An interim analysis is foreseen when the half of the expected events (hyperglycemic peaks) will be observed. In case the results of interim analysis show superiority of the CGM (FSL2) group patients of the second group will be switched.

Detailed Description

Diabete Mellitus (DM) represents an emerging factor with an impact on the severity and the management of symptoms (pain, dyspnoea, fatigue, nausea, vomiting, dehydration) in PC/SC patients leading to a reduced QoL of patients and family members. It has been noted that infrequent Blood Glucose (BG) monitoring might result in a not clear definition about whether symptoms are associated with the dying process or caused by diabetes, leading to inadequate symptoms management.

It is estimated that more than 30% of PC/SC patients can be affected by DM type I or type II. The incidence of diabetes seems to be six times greater in cancer patients than in the general population.

Despite this high incidence, implementation of standard Guidelines on monitoring BG levels in the PC/SC setting is lacking and the existing Guidelines are mainly based on expert experience rather than real data obtained from well design studies as evidenced by a recent review. Currently, the available tool used to evaluate BG in PC/SC patients is mainly represented by the punctual finger-samples procedure, which is usually performed only when there is a suspect of hyperglycemia/hypoglycemia or routinely in PC patients with known DM before meals administration. Punctual finger-samples procedure has many limitations: it is uncomfortable and painful for patients, it requires training to patients and family members by Health Care Providers (HCPs) and requires time to HPCs for preparing/conducting the procedures. As a consequence, BG monitoring in PC/SC patients (especially in home care settings) with known DM and newly diagnosed DM is very poorly and infrequently performed and represents a real unmet medical need.

Recently, a very innovative device, Freestyle Libre 2 (FSL2) (Abbott), has obtained a CE mark for Continuous Glucose Monitoring (CGM) in diabetic patients. The system includes a self-applied sensor with a size of two-stacked quarters, that is easy to apply on the back of the upper arm; it employs a pre-calibrated sensor that measures the tissue glucose concentration repeatedly for two weeks and has a duration of accuracy measurements of 14 consecutive days; interstitial Glucose levels are easily check with a painless one-second scan by a smartphone App or a Reader with results represented by latest glucose concentration and trend direction. The scan with the App or the Reader should be applied at least every 8 hours in order to have the recording of the glucose level. FSL2 has real-time glucose alarms that notify if glucose level is going too low or too high (Free Style Libre 2 User's Manual).

The rationale of the proposed study is based on the CGM system using FSL2, that is highly matching the need of Glucose level monitoring in PC/SC patients with known or newly diagnosed (i.e. iatrogenic) DM. FSL2 has no/very little discomfort for patients and it is not painful, it is easy to apply, it is not time-spending for family members and HCPs and it requires very brief training for patients and family members. The alarm system of FSL2 can aware patients, family members and HCPs at any moment when the glucose level is over a predefined cut off value, allowing to implement the appropriate interventions (i.e. insulin administration or insulin dose adjustment) in order to prevent and manage Symptomatic hyperglycemia crisis. The recent International Consensus on Recommendations on CGM data interpretation are showing that in particularly frail population, Glucose level are maintained for 50% of the time in a range between 70 mg/dL and 180 mg/dL and for 50% of the time in a range between 180 mg/dl and 250 mg/dl. According to that Recommendations, the alarm could be activated when glucose is over a cut off level of 180 mg/dL. The alarm activation allows patients themselves, family members, HCPs to provide patients with the most appropriate intervention (i.e. administration or adjustment of insulin dosage) in order to prevent glucose level reaching the peak of severe hyperglycemia (>250 mg/dl).

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Supportive Care
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Aged > or = 18 years
  • •Diagnosed with advanced oncological disease
  • •Known/newly diagnosed DM according to ADA criteria
  • •Need of a Insulin therapy and need of Glycemia Monitoring with at least three finger pricks/die
  • •Karnofsky Index >= 30
  • •Provision of signed and dated informed consent form

Exclusion Criteria

  • •Diagnosis of all types of Dementia
  • •Presence of severe psychiatric diseases/symptoms
  • •Kidney failure requiring dialysis
  • •Patients with implanted pacemaker

Arms & Interventions

Continuous Glucose Monitoring

Experimental

The FreeStyle Libre 2 Flash Glucose Monitoring System (FSL2) is a CGM device with real time alarms capability indicated for the management of diabetes in persons aged 4 and older. The Sensor holds eight (8) hours of data at a time. In order to have a daily diary of the Glucose level the patients or family or HCP must read the sensor (with reader or app) at least every height (8) hours. Every day at least three (3) scans of the sensor should be performed using the reader or the Smartphone App, generally at wake up in the morning, in the afternoon and at the time to go to sleep.

The alarm system will be activated, so that the Glucose level is over the cut off limit of 180 mmol/L or when it is lower than the cut-off limit of 80 mmol/L, the patient and/or the family members and/or the caregiver will check the Glucose level by scanning the reader/smartphone over the sensor.

Intervention: Continuous Glucose Monitoring (Device)

Standard Care

Active Comparator

This arm will perform the usual standard routine for blood glucose monitoring in patients with insulin therapy, that is represented by at least three finger pricks/die according to the usual standards routine of each center.

Different frequency of finger pricks glucose measurements could be performed on the basis of health care professional patient assessment of each patient's needs.

Intervention: Standard Care (Device)

Outcomes

Primary Outcomes

Evaluate CGM by using FSL2 in preventing severe hyperglycemia peaks

Time Frame: From recruitment until last followup (8 weeks)

First severe hyperglycemic peak (\>250 mg/dL) observed during evaluation

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor
Antea Foundation
Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (6)

Loading locations...