跳至主要内容
临床试验/NCT06148012
NCT06148012已完成不适用

Investigation of Marginal Bone Loss in Implants with Different Surface Properties and Geometric Designs: a Retrospective Clinical Study

Recep Tayyip Erdogan University2 个研究点 分布在 1 个国家目标入组 3 人开始时间: 2023年4月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
3
试验地点
2
主要终点
Marginal Bone Loss around different dental implants

研究概览

简要总结

Purpose: The aim of this study was to investigate the influence of surface characteristics and geometric design on marginal bone loss and bone quality in dental implants.

Materials and Methods: A total of 378 implants from 114 patients were evaluated in this study using panoramic and periapical radiographs. Implants were categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations were conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading. After obtaining measurements of marginal bone loss and fractal analysis data, the significance of differences between groups was statistically evaluated.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Male
接受健康志愿者

入选标准

  • Implants with a minimum length of 8 mm
  • Implants with a minimum diameter of 3.5 mm
  • Availability of panoramic and periapical radiographs at T0 (immediately after surgery) and T1 (3 months after prosthetic loading).

排除标准

  • Presence of a systemic condition hindering dental implant treatment and routine check-ups
  • History of regular alcohol/tobacco use
  • Presence of severe parafunctional habits (bruxism, etc.)
  • Prior grafting procedures before dental implant placement
  • Implant failure

结局指标

主要结局

Marginal Bone Loss around different dental implants

时间窗: 180 days

Number of Participants: 114 Number of Dental Implants: 378 Implants will be categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations will be conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading. The distance between the most coronal part of the implant neck and the most apical part of the defect caused by marginal bone loss(millimeters) will be measured. The magnification ratio will be calculated by comparing the previously recorded implant length with the length measured on the software, allowing the determination of the actual value of MBL.

Fractal values around dental implant radiographs

时间窗: 180 days

A total of 378 implants from 114 patients will be evaluated in this study using panoramic and periapical radiographs. Implants will be categorized into 19 subgroups according to the jaw where they were placed, length, diameter, surface preparation, type of prosthetic superstructure, and neck design. Radiological evaluations will be conducted based on radiographs obtained at the time of implant placement and 3 months after prosthetic loading. And measurement pre op post op fractal values

次要结局

未报告次要终点

研究者

发起方
Recep Tayyip Erdogan University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Mert Karabağ

PhD

Recep Tayyip Erdogan University

研究点 (2)

Loading locations...

相似试验