The Effect of High-Flow Needleless Valve and DualCap Disinfection Devices on Incidence of Catheter-related Bloodstream Infection in Hemodialysis Patients: a Single Center Randomized Controlled Trial
试验速览
- 阶段
- 4 期
- 入组人数
- 102
- 主要终点
- Catheter-related bloodstream infection
研究概览
简要总结
The purpose of this study is to investigate whether the usage of High-Flow Needleless Valve and DualCap Disinfection Devices would reduce the incidence of catheter-related bloodstream infection in hemodialysis patients.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Implanted non-tunneled cuff catheter for any reason and going on blood purified therapy in our centre
- •Have signed information consent form
排除标准
- •Have got bacteremia before catheter implantation
- •Catheter changing in situ
研究组 & 干预措施
Control
In this group, patients will use traditional standard hemodialysis connector and receive typical disinfection management
Only High-Flow Valve
In this group, patients will use High-Flow Needleless Valve instead of traditional standard hemodialysia connector, but still receiving typical disinfection management
干预措施: High-Flow Needleless Valve (Device)
Both Divices
In this group, patients will receive both High-Flow Needleless Valve and DualCap Disinfection Devices in hemodialysis
干预措施: High-Flow Needleless Valve (Device)
Both Divices
In this group, patients will receive both High-Flow Needleless Valve and DualCap Disinfection Devices in hemodialysis
干预措施: DualCap Disinfection Devices (Device)
结局指标
主要结局
Catheter-related bloodstream infection
时间窗: through study completion, an average of 1 year
次要结局
- Number of participants with catheter withdraw for any reason(through study completion, an average of 1 year)
- Number of participants with catheter dysfunction(through study completion, an average of 1 year)
研究者
Rong Xu
vice professor
Peking University First Hospital