跳至主要内容
临床试验/NCT07287176
NCT07287176招募中不适用

Prospective Evaluation of the Pulse Biosciences nPulse™ Vybrance™ Percutaneous Electrode System in Symptomatic Benign Thyroid Nodules (PRECISE-BTN) Study

Pulse Biosciences, Inc.4 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2025年8月21日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
100
试验地点
4
主要终点
Volume Reduction Ratio (VRR)

研究概览

简要总结

The primary objective of this study is to reproduce in a multi-center study results obtained during the feasibility First-In-Human (FIH) study with Prof. Stefano Spiezia, MD (Ospedale del Mare, Naples, Italy) and to monitor additional thyroid-related symptoms and impact of patients quality of life post-ablation using a validated QoL questionnaire.

详细描述

The study design is a prospective, non-randomized, clinical study using the Pulse Biosciences nPulse Vybrance Percutaneous Electrode (PE) System for the treatment of benign thyroid nodules (BTNs) using nanosecond Pulsed Field Ablation (PFA). All participants will receive at least one nsPFA treatment and may be eligible to receive a second treatment at the 6-month follow up visit per physician discretion. All participants will have regularly scheduled ultrasound assessments and administration of questionnaires (e.g., Thy-PRO39 and SF-12) at 1-month, 3 months, 6 months and 12 months post-nsPFA treatment.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
22 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participant is willing and able to provide voluntary, written informed consent to participate in this study and from whom written informed consent has been obtained
  • Participants must be willing and able to comply with study procedures including all follow-up visits
  • Selected nodule is amenable to trans-isthmus approach
  • Nodule is confirmed as benign based on results from one or more of the following diagnostic tests:
  • (Bethesda II) on at least 2 ultrasound guided fine needle aspirations (FNA) or core needle biopsy (CNB);
  • A single benign diagnosis of FNA or CNB when the nodule has benign ultrasound features [American College of Radiology (ACR) Thyroid Imaging Reporting & Data System [TI-RAD] TR 1-3, American Thyroid Association [ATA] very low suspicion];
  • Candidate has a hyperfunctional nodule following 1 ultrasound guided FNA or CNB with or without molecular testing; or
  • Benign (Bethesda III or IV) with two biopsies in addition to molecular testing confirming benign diagnosis
  • Selected nodule is <80.0 ml
  • Participant has normal vocal cord mobility by ultrasound evaluation
  • Participant has presence of compression symptoms, cosmetic concerns or anxiety for which participant requests treatment of the benign thyroid nodule
  • Participant has a solitary thyroid nodule or dominating nodule that is well-defined in multinodular goiter

排除标准

  • Participant has an implantable electronic medical device. (i.e., pacemaker, implantable cardioverter defibrillator)
  • Participant has cystic nodules (< 70% solid components)
  • Participant has calcified nodules
  • Participant is known to be immune compromised
  • Participant had previous neck irradiation
  • Participant has abnormal cervical lymph nodes present during screening visit examination
  • Participant has history of familial thyroid cancer in more than two first-degree relatives
  • Selected nodule previously treated with radiofrequency ablation or ethanol. This does not apply to nodules previously treated with nanosecond Pulsed Field Ablation (nsPFA)
  • Participants currently suffering from a hematological disease or bleeding tendency
  • Selected nodule likely to be in contact with the recurrent laryngeal nerve on ultrasound evaluation
  • Participant has a history of uncontrolled cardiac arrhythmia, uncontrolled hypertension, chronic liver disease or chronic kidney disease (Stage 4-5), or recent history of myocardial infarction or structural heart disease as determined by the Investigator
  • Participant has abnormal contralateral vocal cord function
  • Anesthesia drug allergies
  • Participant is pregnant at the time of screening or within 30 days prior to enrollment
  • Participant has any condition or situation which, in the Investigator's opinion, puts the participant at significant risk, could confound the study results, or may interfere significantly with the participant's participation in the study
  • Use of any investigational device or drug within 30 days prior to enrollment that may confound the results of this study

研究组 & 干预措施

nPulse Vybrance Percutaneous Electrode System Treatment Arm

Experimental

Adult participants who are clinically symptomatic will receive ablation of the benign thyroid nodule using the nPulse Vybrance Percutaneous Electrode System.

干预措施: nPulse Vybrance Percutaneous Electrode System (Device)

结局指标

主要结局

Volume Reduction Ratio (VRR)

时间窗: 6 months post-index procedure

The percentage decrease of thyroid nodule volume measured by ultrasonography after treatment (ablation) using the nPulse Vybrance Percutaneous Electrode System

次要结局

  • Volume Reduction Ratio (VRR) Over Time(1 month, 3 months, 6 months and 12 months post-nPulse Vybrance treatment)
  • Recurrence Rate(6 and 12 months post-nPulse Vybrance treatment)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验