跳至主要内容
临床试验/NCT07510438
NCT07510438招募中不适用

AVS Pulse Intravascular Lithotripsy™ (Pulse IVL™) to Open Vessels With Calcific Walls and Enhance Vascular Compliance and Remodeling for Coronary Artery Disease - A First-in-Human (FIH) Study

Amplitude Vascular Systems, Inc.3 个研究点 分布在 2 个国家目标入组 15 人开始时间: 2026年5月8日最近更新:
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
15
试验地点
3

研究概览

简要总结

A prospective, open-label, multi-site, FIH with up to fifteen (n=15) patients to assess the safety and preliminary effectiveness of the AVS Pulse Intravascular Lithotripsy™ System (Pulse IVL™ System) when used for the treatment of coronary artery disease.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • ≥ 18 years of age
  • Subjects with native coronary artery disease
  • Left ventricular ejection fraction (LVEF) ≥ 35% within 6 months
  • The target lesion must be a single de novo coronary lesion
  • The target lesion stenosis of left anterior descending artery (LAD), right coronary artery (RCA), left circumflex artery (LCX), or ramus intermedius (RI), or of their branches with Stenosis of ≥70% and <100% or Stenosis ≥50% and <70% with evidence of ischemia
  • Lesion length must not exceed 44 mm

排除标准

  • Subject experienced an acute Myocardial Infarction (MI), either ST-segment elevation myocardial infarction (STEMI) or non-ST-segment elevation myocardial infarction (NSTEMI) within 30 days prior to index procedure.
  • Subject has New York Heart Association (NYHA) class III or IV heart failure.
  • Subject has renal failure with serum creatinine >2.5 mg/dL, or chronic dialysis.
  • Subject has a previous stent in the target vessel implanted within last six months.
  • Unprotected LMCA diameter stenosis >30%.
  • Target lesion has a myocardial bridge.
  • Target vessel is excessively tortuous, defined as the presence of 2 or more bends >90 degrees or 3 or more bends >75 degrees.
  • Evidence of aneurysm in target vessel within 10 mm of the target lesion.
  • Target lesion in ostial location (LAD, RCA, LCX, or RI, within 5 mm of ostium) or in an unprotected LMCA.
  • Target lesion is a bifurcation with ostial diameter stenosis ≥30%.
  • Any previous stent within 10 mm of the target lesion.

研究组 & 干预措施

Pulse Intravascular Lithotripsy™ (Pulse IVL™)

Experimental

Pulse Intravascular Lithotripsy™ (Pulse IVL™) to open vessels with calcific walls

干预措施: Pulse Intravascular Lithotripsy (Pulse IVL) (Device)