Evaluation of Fluid Infusion With LifeFlow for Patients With Suspected Septic Shock
试验速览
- 阶段
- 不适用
- 状态
- 撤回
- 主要终点
- Time of initiation and termination of each fluid bolus administration
研究概览
简要总结
The LifeFlow rapid infusion device is a handheld manually-operated device that has been shown in early trials to increase the rate of bolus fluid infusion up to 3 times the rate of delivery attributed to conventional rapid infusion devices. The device addresses other technical barriers to fluid resuscitation, including reducing complexity and provider fatigue. LifeFlow utilizes standard IV or intraosseous (IO) vascular access devices to quickly and efficiently deliver appropriate volumes of crystalloid fluid to patients during emergent fluid resuscitation. The purpose of this study is to determine if intravenous fluids can be administered more rapidly and efficiently with the use of the LifeFlow rapid infusion device compared to the current standard techniques in adult patients who present to the Emergency Department with septic shock.
详细描述
Patients with conditions such as septic shock, anaphylaxis, and hypovolemic shock may require rapid fluid administration to restore blood pressure and tissue perfusion. Newly Updated Surviving Sepsis Campaign (SSC) guidelines call for patients with septic shock to receive a 30ml/kg intravenous (IV) fluid challenge within 1 hour of emergency department (ED) arrival, with improved outcomes shown with early fluid infusion. Patients with shock and severe hypotension may require even more rapid fluid treatment, up to 4ml/kg/min. While excess fluid infusion may be associated with harm, early fluid infusion for the reversal of shock can reduce the need for subsequent interventions, ultimately leading to improved patient outcomes. This may be especially true in patients with hypotension, who are at greater risk of death if not treated quickly, as a single episode of hypotension in patients with sepsis is correlated with a significantly increased risk of death.
In patients who require IV fluid bolus therapy, technical barriers such as slow infusion rates, technically complex infusion devices, and inadequate nursing resources may lead to delay in fluid administration and inadequate resuscitation. As recommended by the SSC guidelines, patients receiving fluid bolus therapy for septic shock require frequent reassessment of clinical response. With current fluid delivery techniques, the ability to reassess quickly and relate fluid administration directly to markers of hemodynamic improvement is limited.
The LifeFlow rapid infusion device is a handheld manually-operated device that has been shown in early trials to increase the rate of bolus fluid infusion up to 3 times the rate of delivery attributed to conventional rapid infusion devices. The device addresses other technical barriers to fluid resuscitation, including reducing complexity and provider fatigue. LifeFlow utilizes standard IV or intraosseous (IO) vascular access devices to quickly and efficiently deliver appropriate volumes of crystalloid fluid to patients during emergent fluid resuscitation.
The purpose of this study is to determine if intravenous fluids can be administered more rapidly and efficiently with the use of the LifeFlow rapid infusion device compared to the current standard techniques in adult patients who present to the Emergency Department with septic shock.
Primary Hypothesis
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult ED patients ≥ 18 years of age
- •Patients with hypotension (Systolic Blood Pressure (SBP) < 90) mmHg or Mean Arterial Pressure (MAP) < 65 mmHg) and at least one of the following:
- •Temperature > 101 F (38.3 C) or < 96.8 F (36.0 C)
- •Respiratory Rate (RR) > 22 bpm
- •Heart Rate (HR) > 90/min
- •Patients who will be determined by treating emergency physician to receive rapid fluid bolus for hypotension
- •Patients with adequate cardiac windows
- •EF is 35% or greater
- •No increased number of B lines per rib interspace (3 or more) in multiple locations on lung ultrasound
排除标准
- •Heart failure by history or Ejection fraction (EF) < 35 percent on pre-enrollment Point of care (POC) Echocardiogram
- •History of End stage Renal disease
- •History of End stage lung disease
- •Lymphocyte count < 50mm/m3 or Absolute Neutrophil Count < 500
- •Transferred from another facility
- •Requirement for immediate surgery
- •Patients with 14 Gauge catheters or larger
- •Concurrently on vasopressors or inotrope therapy
- •Patients or legally acceptable representatives unable to provide consent
- •Non-sepsis related primary diagnosis including: acute cerebral vascular event, acute coronary syndrome, acute pulmonary edema, status asthmaticus, major cardiac arrhythmia, active gastrointestinal hemorrhage, seizure, drug overdose, burn or trauma, myocardial infarction or active hemorrhage
- •Incarcerated patients
- •Requirement for immediate surgery
- •Known pregnancy
研究组 & 干预措施
Control
After obtaining the consent, the subject will have a bedside ultrasound performed by the study investigator after receiving 500 ml of intravenous fluid bolus. The images will be recorded on ultrasound machine hard drive for future review. If the bedside ultrasound findings determine that the subject is not fluid responsive, subjects will be excluded from the study. If the subject is determined to be fluid responsive, the above listed outcome measures will be collected. Ultrasound will be repeated after every 500 ml bolus if the patient continues to receive IV fluids which will be determined by the treating physician. Ultrasound measurements and other parameters listed above will be collected throughout the ED and hospital stay.
LifeFlow group
LifeFlow device will be used to administer intravenous fluids in this group. LifeFlow is a FDA approved device to administer IV fluids. Subject will have a bedside ultrasound performed by the study investigator after receiving 500 ml of intravenous fluid bolus. The images will be recorded on ultrasound machine hard drive for future review. If the bedside ultrasound findings determine that the subject is not fluid responsive, subjects will be excluded from the study. If the subject is determined to be fluid responsive, the above listed outcome measures will be collected. Ultrasound will be repeated after every 500 ml bolus if the patient continues to receive IV fluids which will be determined by the treating physician. Ultrasound measurements and other parameters listed above will be collected throughout the ED and hospital stay.
干预措施: Life Flow (Device)
结局指标
主要结局
Time of initiation and termination of each fluid bolus administration
时间窗: Up to 30 days
Volume of each fluid bolus administration
时间窗: Up to 30 days
次要结局
- Peak Fluid overload-defined as the maximum percentage of fluid overload during the first 72 h after initiation of invasive Mechanical Ventilation(Up to 30 days)
- Length of stay in the Emergency department, Intensive care unit, and total hospital length of stay(Up to 30 days)
- Resolution of abnormal blood pressure (measured at time of arrival, diagnosis and following each fluid bolus)(Up to 30 days)
- Number of subjects received a central line(Up to 30 days)
- Percent of fluid overload (FO) was calculated using the following formula: [(total fluid intake (L) - total fluid output in liters (L)) / (admission weight in kilograms)*100](Up to 30 days)
- Time vasopressors are started and discontinued(Up to 30 days)
- Assessment of Adverse effects, including rate of Intravenous fluid infiltration(Up to 30 days)
- Time from initial order to completion of first fluid bolus(Up to 30 days)
- Resolution of abnormal heart rate (measured at time of arrival, diagnosis and following each fluid bolus)(Up to 30 days)
- Time to administration of antibiotics(Up to 30 days)
- Type of vasopressors used(Up to 30 days)
- Need for endotracheal intubation/mechanical ventilation(Up to 30 days)
- Number of ventilator-free days(Up to 30 days)
研究者
Srikar Adhikari
Associate Professor
University of Arizona