跳至主要内容
临床试验/NCT01943149
NCT01943149Unknown不适用

E-MAX 2nd Generation Vitamin E Polyethylene On BIOLOX Delta Ceramic Heads

Renovis Surgical Technologies, Inc.1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2014年1月最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
50
试验地点
1
主要终点
E-Max liner wear rate

研究概览

简要总结

The purpose of this study is to monitor outcomes of total hip arthroplasties performed with E-MAX polyethylene and BIOLOX Delta Ceramic head. Polyethylene has been used as a bearing surface in total joint replacements for half of a century. Radiation, the most common form of sterilization, unfortunately it results in the creation of free radicals (atoms or molecules that cause chemical reactions with other substances) within the materials which cause the breakdown of the polyethylene. Second generation antioxidant polyethylene, Renovis E-MAX, mechanically blends in Vitamin E as an antioxidant. This helps eliminate free radicals while maintaining mechanical strength. The theory is that E-MAX will be a safe and long lasting bearing surface in total hip arthroplasty that meets or exceeds current wear rates after being placed in a patient.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient is under 65 years of age
  • Patient's health status qualifies as ASA 1 or ASA 2
  • Patient is willing to commit to long term follow (study duration is 10 yrs)

排除标准

  • Allergy to any materials used in hip implant
  • Unwillingness to participate in long term follow-up
  • Diagnosis of inflammatory arthritis
  • Simultaneous bilateral total hip arthroplasty is recommended.
  • Patient's health status qualifies as ASA 3 or greater.
  • Patient is over the age of 65 of age

结局指标

主要结局

E-Max liner wear rate

时间窗: Change from baseline to 10 years post-operative

This measure's purpose it to look at the longevity of our product. Radiographs will be taken at standard checkpoints over the course of 10 years. Radiographic analysis will be done to assess wear rates of the E-Max liner over the course of the 10 year study. Wear rates will then be compared to other products that have already been studied and published in hopes of finding that E-Max's wear rates are at least as good if not better than comparative products on the market.

次要结局

  • Patient Function and Mobility(Change from Pre-operative to 10 years post-operative)

研究者

发起方
Renovis Surgical Technologies, Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...