Octad Study: Evaluation of the Effectiveness of the Octopolar Lead in Patients With Failed Back Surgery Syndrome With Low Back and/or Leg Pain During a One Year Follow-up Period
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 发起方
- 入组人数
- 80
- 试验地点
- 16
- 主要终点
- Pain suppression in low back and/or leg
研究概览
简要总结
Spinal cord stimulation (SCS) has been used for over 40 years to treat neuropathic pain. Various clinical studies have shown a beneficial effect of SCS on pain in patients with Failed Back Surgery Syndrome (FBSS). Since more than 2 years the 8-contact points Octad lead has been used and replaced the 4-contact points Quad lead. Even though it seems that eight electrodes has potential advantage over the four electrodes in case of lead migration or disease progress, no clinical data have been published on the effectiveness of SCS using the octopolar epidural lead. The Octad study intents to assess the effectiveness and technical performance of SCS with the Octad® lead for treatment of chronic pain. This study is not set up as a comparison study between the Octad lead and other SCS leads, such as the Quad lead, because the Octad lead is used in most eligible FBSS patients as the standard of care lead.
The study intends to:
- evaluate the effectiveness of SCS with the Octad® lead on chronic pain in Failed Back Surgery Syndrome patients after 12 months of treatment.
- collect safety data for SCS with the Octad® lead in patients with refractory chronic pain.
详细描述
The use of Spinal Cord Stimulation (SCS) for pain control has already a history of more than 40 years. In SCS, a lead is positioned in the epidural space on the dorsal aspect of the spinal cord so as to produce stimulation induced paraesthesia in the painful area. During the last decades many articles have been published, clearly indicating the effectiveness and safety of SCS with quadripolar leads in the pain management of chronic neuropathic pain, and in particular Failed Back Surgery Syndrome (FBSS). Randomized controlled trials demonstrated that compared with re-operation, SCS provides effective pain relief for at least 3 years and compared with conventional non-surgical neuropathic pain management for at least 2 years.
However, SCS-related complications can occur, that can be divided into surgical complications and hardware complications. The hardware technology has substantially improved over the years. Moreover, electrodes have become smaller in shape and easier to navigate through the epidural space; and finally, internal pulse generators have new programming capabilities and a longer battery life span. All these technological developments led to the application of minimally invasive percutaneous stimulation trials for a variety of patients with chronic neuropathic pain. Turner et al performed a meta-analysis of spinal cord stimulation for failed back surgery syndrome publications and reported hardware complications of 24% lead migration, 7% lead failure and 2% pulse generator failure. While this analysis evaluated studies using older hardware systems, there is first evidence that the rate of these complications is lower currently with new systems. In the recently published PROCESS paper, also using quadripolar electrodes, long term follow-up showed that hardware complications were 14%: lead migration, 3% lead failure and no pulse generator failures.
Generally, patients with radicular pain to the lower extremities respond better to spinal cord stimulation than patients with isolated axial low back pain. However, a few studies have shown that axial low back pain in combination with bilateral leg pain, also respond well to spinal cord stimulation. Both four (e.g. quadripolar Quad lead) and eight (e.g. octapolar Octad® lead) electrodes were shown to be effective in treatment of low back and lower extremity pain, with no apparent advantage of one system over the other. In the recent PROCESS study publication, the reduction of SCS on low-back pain was not-statistically significant when compared to baseline. Even though it seems that eight electrodes may have the potential advantage in case of lead migration or disease progress, no clinical data have been published on the effectiveness of SCS using the octopolar epidural lead. The Octad study is a prospective, multi-center, open-label, non-randomized, interventional study designed to assess the effectiveness and technical performance of SCS with the Octad® lead for treatment of chronic pain. This study is not set up as a comparison study between the Octad lead and other SCS leads, such as the Quad lead, because the Octad lead is used in most eligible FBSS patients as the standard of care lead.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •FBSS patients with neuropathic pain in low-back and/or legs who have not reached their therapy goal with other treatment interventions
- •≥ 18 years of age
- •Chronic pain as a result of FBSS that exists for at least 6 months
- •Mean pain intensity in the legs should be 5 or higher measured on Visual Analogue Scale (VAS).
- •Patient has been informed of the study procedures and has given written informed consent.
- •Patient willing to comply with study protocol including attending the study visits.
排除标准
- •Expected inability of patients to receive or properly operate the spinal cord stimulation system
- •History of coagulation disorders, lupus erythematosus, diabetic neuropathy, rheumatoid arthritis or morbus Bechterew
- •Active malignancy
- •Addiction to any of the following: drugs, alcohol (5E/day) and/or medication
- •Evidence of an active disruptive psychiatric disorder or other known condition significant enough to impact perception of pain, compliance to intervention and/or ability to evaluate treatment outcome as determined by investigator
- •Immune deficiency (HIV positive, immunosuppressive, etc.)
- •Life expectancy < 1 year
- •Local infection or other skin disorder at site of incision
- •Other implanted active medical device
- •Participation in another clinical trial.
研究组 & 干预措施
SCS
patients receiving SCS for chronic leg and/or back pain.
干预措施: Spinal cord stimulation with eight polar electrode (Device)
结局指标
主要结局
Pain suppression in low back and/or leg
时间窗: 12 months
Evaluate the evolution of pain control with the octopolar Octad® lead assessed by a decrease in VAS for leg (and low-back pain separately, if applicable) during 12 months follow-up. Actual pain, the least pain during the last week and the worst pain during the last week are scored.
次要结局
- adverse events related to SCS(12 months)
- preferred stimulation settings(12 months)
- quality of life(12 months)
- sleep(12 months)
- pain medication intake(12 months)
- Healthcare resource utilization(12 months)
研究者
Rik Buschman, PhD
Principal Scientist
Medtronic Neuromodulation Europe