跳至主要内容
临床试验/NCT05370599
NCT05370599终止2 期

Hypertension in Young Adults Trial

University of California, San Francisco1 个研究点 分布在 1 个国家目标入组 36 人开始时间: 2022年4月15日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
2 期
状态
终止
入组人数
36
试验地点
1
主要终点
Achieved systolic blood pressure

研究概览

简要总结

This is a pilot randomized controlled trial which will test the effect of 3 different anti-hypertensive agents and 3 different strategies of engaging young adults in home blood pressure monitoring on blood pressure control, with secondary outcomes focused on quality of life and adverse events.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Factorial
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • 18-40 years of age
  • Diagnosis of hypertension or receiving anti-hypertensive therapy OR Has clinical BP readings >130/80 mmHg that would meet the definition of hypertension and have home BP readings >=125/80 mmHg

排除标准

  • are or are planning to become pregnant, due to inability to take multiple classes of anti- hypertensive agents
  • are marginally housed, due to concerns regarding routine follow-up
  • are actively participating in a different interventional trial that may affect blood pressure
  • are unwilling to consent to participate
  • institutionalized individuals or prisoners
  • are actively abusing illicit drugs or alcohol
  • have a history of poor or doubtful compliance (e.g., frequently missed appointments)
  • have cognitive impairment prohibiting participation in the study
  • History of allergy to any of the randomized medications
  • Serum potassium >5.5 meq/L at the screening visit
  • BP > 160/100 mmHg in clinic (stage II hypertension), regardless of whether patient is on therapy
  • eGFR < 30 mL/min/1.73 m2

研究组 & 干预措施

Amlodipine 2.5 mg + Home BP monitoring with cuffed device

Active Comparator

Use of at least the minimum dose of amlodipine and use of a home BP monitoring device for BP monitoring

干预措施: Home BP monitoring with cuffed device (Device)

Chlorthalidone 12.5 mg + Home BP monitoring with cuffed device

Experimental

Use of at least the minimum dose of chlorthalidone and use of a home BP monitoring device for BP monitoring

干预措施: Home BP monitoring with cuffed device (Device)

Losartan 12.5 mg daily + home BP monitoring with cuffed device

Experimental

Use of at least the minimum dose of losartan and use of a home BP monitoring cuffed device only for BP monitoring

干预措施: Home BP monitoring with cuffed device (Device)

amlodipine 2.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP patch (Device)

Chlorthalidone 12.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP patch (Device)

Losartan 12.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP patch (Device)

amlodipine 2.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP watch (Device)

chlorthalidone 12.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP watch (Device)

losartan 12.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Home BP monitoring with cuffed device + BP watch (Device)

Amlodipine 2.5 mg + Home BP monitoring with cuffed device

Active Comparator

Use of at least the minimum dose of amlodipine and use of a home BP monitoring device for BP monitoring

干预措施: Anti-hypertensive agent: amlodipine (Drug)

Chlorthalidone 12.5 mg + Home BP monitoring with cuffed device

Experimental

Use of at least the minimum dose of chlorthalidone and use of a home BP monitoring device for BP monitoring

干预措施: Anti-hypertensive agent: Chlorthalidone (Drug)

Losartan 12.5 mg daily + home BP monitoring with cuffed device

Experimental

Use of at least the minimum dose of losartan and use of a home BP monitoring cuffed device only for BP monitoring

干预措施: Anti-hypertensive agent: Losartan (Drug)

amlodipine 2.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Anti-hypertensive agent: amlodipine (Drug)

Chlorthalidone 12.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Anti-hypertensive agent: Chlorthalidone (Drug)

Losartan 12.5 mg daily + home BP monitoring with patch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a patch for BP monitoring

干预措施: Anti-hypertensive agent: Losartan (Drug)

amlodipine 2.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Anti-hypertensive agent: amlodipine (Drug)

chlorthalidone 12.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Anti-hypertensive agent: Chlorthalidone (Drug)

losartan 12.5 mg daily + home BP monitoring with watch

Experimental

Use of at least the minimum dose of this agent and use of a home BP monitoring device only + a watch for BP monitoring

干预措施: Anti-hypertensive agent: Losartan (Drug)

结局指标

主要结局

Achieved systolic blood pressure

时间窗: Month 6

Systolic blood pressure will be collected using at home cuffed devices. The readings at end of the pilot trial (or most recent readings available) will be used for analysis of the primary outcome.

次要结局

  • Adherence to home BP monitoring(Between month 0 and 6)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验