跳至主要内容
临床试验/NCT03174210
NCT03174210已完成不适用

Effects of Supplemental Oxygen Delivered by a Portable Oxygen Concentrator Compared to a Liquid Oxygen Device in Hypoxemic COPD Patients at Rest

Schön Klinik Berchtesgadener Land1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2017年5月2日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
1
主要终点
Difference between LOD and POC in Partial pressure of oxygen levels

研究概览

简要总结

The aim of this study is to investigate the effects of supplemental oxygen on blood oxygenation at rest in Patients with severe to very severe COPD comparing the portable oxygen concentrator (Activox™ 4L) to a liquid continuous oxygen device (Companion®).

详细描述

It has been proven that supplemental oxygen increases oxygen saturation and reduces dyspnea in hypoxemic COPD Patients. There are different oxygen delivery systems available, some of them operating with liquid oxygen and others by concentrating the ambient air (concentrators). An advantage of the concentrator system is, that there is no refill required, but only a power plug and plug socket, enabling the patient for higher mobility and to be more autonomous. There are only few publications about whether portable oxygen concentrators have a comparable efficiency on oxygen saturation to liquid oxygen devices with continuous flow (LOD) or not. Until now there are no official recommendations about how to convert the oxygen flow rate for LOD (liter per minute) into the corresponding level of the POC.

Therefore, we investigate the comparability of the portable oxygen concentrator Activox™ 4L (POC) to a liquid oxygen device (Companion®) in 30 hypoxemic COPD patients at rest.

As a baseline assessment, the patients will receive a bodyplethysmography, blood gas analysis without using supplemental oxygen and an evaluation of the diffusion capacity of the lung for CO.

The study will be conducted on 2 consecutive days. 15 patients will be randomized into two different groups: First group will start with POC and will continue the following day with LOD; The second group will start with LOD and continue with POC (cross-over design). All patients will use the same oxygen devices during the study assessments (LOD: Companion 1000 (CE 0050), Chart Industries Inc., Garfiel Heights, OH, USA; POC: Activox™ 4L, Inovalabs Inc., Texas, USA). On both days of the study, patients will be connected to one of the two systems via nasal cannula for a total time period of 40 minutes, while the patient remains in a sitting position without talking. The oxygen flow rate starts at 1liter/min (LOD) or Level 1 (POC) and will be increased every 10 minutes to the next higher level until the maximum of 4l/min (LOD) or level 4 (POC) is reached. Blood gases were taken and breathing frequency will be recorded at the end of each Oxygen Level.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
40 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • COPD patients with hypoxemia at rest (paO2 < 55 or 60 mmHg, according to the recent supplemental oxygen guidelines [Hadringe, M., et al., British Thoracic Society guidelines for home oxygen use in adults. Thorax,
  • 70 Suppl 1: p. i1-43.]
  • Participation in an inpatient pulmonary rehabilitation program (Schön Klinik BGL)
  • Written informed consent

排除标准

  • The Need of more than 4 Liter/min Oxygen at rest to achieve PaO2 > 55 or 60mmHg
  • Signs of acute exacerbation
  • General exclusion criteria for exercise tests, e.g. acute coronary syndrome, acute myo- or pericarditis, acute lung embolism, pulmonary infarction, acute uncontrolled heart insufficiency

研究组 & 干预措施

COPD patients with delivery order 1, 2

Experimental

Patients will use two different Oxygen devices at rest (1.liquid oxygen device (Companion R), 2. portable Oxygen concentrator (Activox TM 4L))

干预措施: liquid oxygen device (LOD) (Device)

COPD patients with delivery order 1, 2

Experimental

Patients will use two different Oxygen devices at rest (1.liquid oxygen device (Companion R), 2. portable Oxygen concentrator (Activox TM 4L))

干预措施: portable oxygen concentrator (POC) (Device)

COPD patients with delivery order 2,1

Experimental

Patients will use two different Oxygen devices at rest (1. portable Oxygen concentrator (Activox TM 4L), 2. liquid oxygen device (Companion R))

干预措施: liquid oxygen device (LOD) (Device)

COPD patients with delivery order 2,1

Experimental

Patients will use two different Oxygen devices at rest (1. portable Oxygen concentrator (Activox TM 4L), 2. liquid oxygen device (Companion R))

干预措施: portable oxygen concentrator (POC) (Device)

结局指标

主要结局

Difference between LOD and POC in Partial pressure of oxygen levels

时间窗: after 10 minutes of each LOD step compared to 10 minutes of each POC step

PO2 values between LOD and POC at comparable Levels of oxygen supply (1liter/minute LOD will be compared to Level 1 of POC until 4liters/Minute LOD to Level 4 of POC)

次要结局

  • Difference between LOD and POC in Partial pressure of carbon dioxide levels(after 10 minutes of each LOD step compared to 10 minutes of each POC step)
  • Change of partial pressure of Oxygen from one POC step to the next step(after 10 minutes of one POC step compared to after 10 minutes of the next POC step)
  • Change of partial pressure of carbon dioxide from one POC step to the next step(after 10 minutes of one POC step compared to after 10 minutes of the next POC step)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Klaus Kenn

Prof. Dr. Klaus Kenn

Schön Klinik Berchtesgadener Land

研究点 (1)

Loading locations...

相似试验